Similar Projects
Last Updated | 02/02/2023 03:47 PM |
Project Title | Maintenance Garage Kentucky Transportation Cabinet |
Physical Address | View project details and contacts |
City, State (County) | Madisonville, KY 42431 (Hopkins County) |
Category(s) | Commercial, Green Building, Heavy and Highway, Sewer and Water |
Sub-Category(s) | LEED Certified, Site Development, Warehouse/Storage, Water Lines |
Contracting Method | Competitive Bids |
Project Status | Contract Award, Construction start expected January 2023 |
Bids Due | View project details and contacts |
Estimated Value | $431,237 [brand] Estimate |
Plans Available from | Copy Center |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | ACCOUNT NO. 609-C940-Z001-85A The project is to convert an existing building to a maintenance garage for the Kentucky Transportation Cabinet, District 2. The existing building is a 21,000 square feet pre-engineered metal building with metal wall and roof panels and vinyl-faced roof and wall insulation. The existing structural system consists of a pre-engineered steel frame skeleton with conventional poured in place concrete shallow foundations, piers, grade beams and concrete floor slabs. The existing PEMB structure will be modified by the removal of an existing interior steel column and the addition of new framing and foundations to support the existing structure. The renovation work will provide new toilets, a shower room and mechanical room. Interior partitions will be light gauge steel framing with gypsum board surface and sound batt insulation. Pedestrian doors will be hollow metal. Overhead sectional doors are existing, to remain. The remainder of the building will be shop area. Site work consists of cutting and patching existing surfaces for installation of underground utilities. Site furnishings include flagpole. Water service is existing from municipal system, sanitary will gravity flow to municipal system. Existing plumbing fixtures will be demolished, and new plumbing will be installed in the renovated area. The building will utilize existing natural gas for heat. Ventilation will be restroom exhaust. Shop area will be heated with existing units and ventilated with existing exhaust fans. Existing electric service is to remain. Electrical work in the renovated area includes a 120/240V power distribution system and LED lighting. The existing automatic sprinkler system will be retained and modified as needed in the renovated area. |
||||||||||||||||||||||||||||||||||
Details | 21,000 SF.
|
||||||||||||||||||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||||||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |