Similar Projects
Reported | 02/22/2020 12:00 AM |
Project Title | Renovate Survival Equipment Shop at WPAFB |
Physical Address | View project details and contacts |
City, State (County) | Wright Patterson Air Force Base, OH (Greene County) |
Category(s) | Government/Public |
Sub-Category(s) | Misc. Buildings |
Contracting Method | Design-Build. Competitive Bids. |
Project Status | Accepting Letters of Interest |
Bids Due | View project details and contacts |
Estimated Value | $5,000,000 to $10,000,000 |
Plans Available from | Federal Agency |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | Renovate Building 34035, located at Wright Patterson Air Force Base, to include demolishing, disposal, and renovating office spaces to accommodate 445 Aircrew Flight Equipment (AFE), Survival, Evacuation, Resistance & Escape (SERE), and Deployment for Training (DFT) personnel and mission. Reconfigure the interior administrative, training, and industrial space to accommodate revised shop areas and open office planning (estimated combined square footage of 22,450 square ft). Reconfigure interior HVAC, power, and lighting systems to support the revised floor plan, and replace lights with LED fixtures. Provide fire suppression, detection, and alarm systems, to include mass notification capability. Replace exterior metal siding. Replace exterior doors, frames and hardware. Replace the internal gutter system with an exposed gutter and downspout system tied into the underground storm drains. Repair all associated leaks. Replace the roof system. Regrade ground to slope away from the facility. Remove abandoned exterior HVAC equipment and concrete pads. Upgrade utility connections to the facility. Use energy efficient and corrosion resistant materials where life cycle cost effective. Perform asbestos/LBP survey to determine if HAZMAT is present and requires abatement, preliminary seismic structural evaluation, and lightning protection risk assessment per UFC 3-501-01. Abate HAZMATS and correct seismic deficiencies. Raise ceiling height/roof height in raft inspection area to provide approximately 20-foot clear space. Provide foundations, columns, and structural system. Construct personnel canopies for inclement weather protection. Construct a mechanical pad. Connect the facility to the privatized natural gas system. Square footage estimates include installing approximately 1,700 SF of new canopies, raising 3,500 SF of roof, and building a new 1,700 SF drying tower. |
||||||||||||||||||||||||||||||||
Details |
|
||||||||||||||||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||||||||||||||||
Project Documents |
![]() Engineered Spec Sheet ![]() Architectural Plans ![]() Other Documents |