Similar Projects
Last Updated | 07/24/2023 12:32 PM |
Project Title | Joseph F. Weis Jr. U.S. Courthouse Backfill Project |
Physical Address | View project details and contacts |
City, State (County) | Pittsburgh, PA 15219 (Allegheny County) |
Category(s) | Government/Public |
Sub-Category(s) | Capitol/Court House/City Hall |
Contracting Method | Competitive Bids |
Project Status | Bidding, Request for Qualifications, Construction start expected March 2023 |
Bids Due | View project details and contacts |
Estimated Value | $10,000,000 [brand] Estimate |
Plans Available from | Agency's Affiliate |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | Veterans Affairs Southern Nevada Healthcare System Statement of Work 2237#: 593-22-2-736-0024 CONTRACT TITLE: VA Southern Nevada Healthcare System (VASNHS) Physical Security Deficiency Upgrade REQUIREMENTS/SCOPE: Vendor shall provide a turn-key solution to remove and replace old Physical Access Control System (PACS) and install new Milestone camera system at Laughlin CBOC, replace current PACS system at Pahrump CBOC, install motion/intrusion alarms through-out all VASNHS Federal facilities and replace Facility Commander WUI/RP8 boards to be compatible with LENEL OnGuard v8. SPECIFIC TASKS: LAUGHLIN CBOC: Remove existing C-Cure software access control and install LENEL OnGuard v8 and install 11 new Lenel access-controlled doors (replace 8 existing and install 3 new); install new Intrusion system in IDF room. Remove existing PELCO CCTV system and replace with Milestone system; install 8 new AXIS P3375-V cameras. New PACS and Milestone Camera system need to be integrated into the LENEL system at VA Medical Center Dispatch Office/systems. PAHRUMP CBOC: Install new LENEL workstation; program new IP address to the LENEL controller; merge current license and integrate into the LENEL system at VA Medical Center Dispatch Office/systems. VA Medical Center: Replace existing LENEL WUI boards (appx. 900) for updated LENEL mercury boards for compatibility with LENEL OnGuard v8. Replace boards in LSP enclosures/power supplies in IDF rooms located above doors and use existing wiring. Install 37 AXIS P3375-V cameras over PXYIS areas and integrate into the Milestone camera system located in Dispatch Office |
||||||||||||||||||||||||||||||||||||
Details | 31,000 SF.
|
||||||||||||||||||||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||||||||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |