Similar Projects
Cedar Highlands BLM Fuel Break Maintenance Cut and Pile
Results
Less than $50,160 est. value
Cedar City, UT

Parleys MS4
Results
UT

12,000 Gal Fuel Tank
Post-Bid
Cedar City, UT 84721

Zion Ponderosa Wood Fuels Reduction
Post-Bid
Kanab, UT 84741

Gas Line & Fuel Swap at Tooele Army Depot
Post-Bid
$5,000,000 to $10,000,000 est. value
Tooele, UT

Malcomb Springs 3 Million Gallon Water Tank
Post-Bid
$4,000,000 to $4,500,000 est. value
Spanish Fork, UT

Medical Gas Line Installation
Post-Bid
Salt Lake City, UT

New Utah State Correctional Facility Construction Project
Post-Bid
Layton, UT

Fort Douglas 3 Mg Tank Project
Results
Less than $5,898,874 est. value
Salt Lake City, UT

Trailer Mounted Fuel Tank Scrubbing and Filtration Unit
Results
Salt Lake City, UT 84116

Bulk Fuel Tanks
Post-Bid
Springville, UT 84663

Last Updated 02/15/2021 10:01 AM
Project Title

Upgrade Fuel Tanks

Physical Address View project details and contacts
City, State (County) Riverton, UT   (Salt Lake County)
Category(s) Sewer and Water
Sub-Category(s) Fuel/Chemical Tanks and Lines
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Water Department Fuel Tank: Re-locate the existing double wall, above ground, 3,500 gallon split fuel tank from public works to water department. Prior to moving tank install a concrete pad 13' x 29' x 8" thick on 4" of road base, 95% compaction, with #4 rebar every 18" on center, City Staff will excavate the site. Furnish and Install protective bollards around the tank. Connect this fuel tank to an existing tank at the site to integrate the fueling system in order for them to operate as one tank. Public Works Fuel Tank: Furnish and install a double wall, above ground, 9,000 gallon split tank, (6,000 gal gas & 3,000 gal diesel). Exterior painted, interior bare. Tank must meet all Utah and U.S. Governmental standards and regulations. Tank must be UL-142 with NFPA30 rated. Connect new tank to existing fueling system.

Details

Division 02 - Existing Conditions, Subsurface Investigation.
Division 03 - Concrete, Concrete Reinforcing, Cast-in-Place Concrete.
Division 05 - Metals, Structural Metal Framing, Metal Decking.
Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Facility Fuel Piping, Facility Fuel-Storage Tanks.
Division 31 - Earthwork, Clearing and Grubbing, Grading.
Division 32 - Exterior Improvements, Fences and Gates.
Division 33 - Utilities, Storm Drainage Utilities.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents