Similar Projects
Power Purchase Agreement (PPA) for Projects
Bidding
Towson, MD

Z--Upgrade Switchgear and Distribution - Baltimore
Post-Bid
$5,000,000 to $10,000,000 est. value
Baltimore, MD 21201

Generator Systems Corrective and Preventative Maintenance Services at MPT
Term Contract
Post-Bid
Owings Mills, MD 21117

N--LED Lighting Project for Baltimore WSC 2
Results
Less than $70,000 est. value
Catonsville, MD 21228

Curtailment Service Provider
Term Contract
Results
Baltimore, MD

Emergency Power Generator Service and Transfer Switches
Post-Bid
Less than $50,000 est. value
Baltimore, MD 21120

Electrical Services for 707/211 SHA HQ Complex
Term Contract
Results
$1,000 to $100,000 est. value
Baltimore, MD

Energy Performance Contracting Services
Post-Bid
Towson, MD 21204

Penn Street Garage LED Lighting Upgrade
Results
Baltimore, MD 21201

N063-- Water Detection
Post-Bid
Baltimore, MD

Generator: 36KW -Dot - Bureau: 79-00 - Color: White
Results
Baltimore, MD 21202

Light-Emitting Diode (LED) Televisions
Post-Bid
Baltimore, MD 21215

Conduit System Reconstruction at Various Locations Citywide
Results
$6,000,000 to $9,000,000 est. value
Baltimore, MD 21200

Energy Efficiency Project- 94 Unit Apartment Complex
Post-Bid
Catonsville, MD 21228

Repair of Pirimeter Lighting - Paatuxent Institution
Results
Towson, MD 21286

Last Updated 02/06/2020 08:34 AM
Project Title

William Preston Lane Jr. Memorial Bridge (WPL) Police Building Generator Replacement

Physical Address View project details and contacts
City, State (County) Baltimore, MD 21224   (Baltimore County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value $100,001 to $500,000
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

1.Removal of the existing generator, fuel tank, automatic transfer switch and related feeders, and replacement with a new generator and automatic transfer switch including fuel tanks, fuel pipes, concrete pad, protective bollards, and related feeders. 2.All electrical work required to be done inside and outside buildings. 3.Install manual transfer switch with feeder tap box for temporary generator. 4.Special Warranty (Generator): Five years from date of Substantial Completion. Manufacturer’s standard from in which manufacturer agrees to repair or replace components of packaged engine generators and associated auxiliary components that fail in materials or workmanship within specified warranty period. 5.Contract Warranty: Five years from date of Substantial Completion. Warranty shall include repair, parts, labor, lubricating oil, filters, anti-freeze and preventive maintenance as recommended by manufacturer. 6.Furnish and install new generator, generator platform and steps, automatic transfer switches, and manual transfer switches at the following facility.

Details

Division 26 - Electrical.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents