Similar Projects
Evaporative Cooler Services
Bidding
Albuquerque, NM

Removal and Replacement of HVAC Systems
Post-Bid
Albuquerque, NM

Ford Utilities Cooling Tower Repairs
Post-Bid
Albuquerque, NM 87131

Ernie Pyle Middle School Re-Roofing and HVAC Upgrades
Results
Albuquerque, NM 87105

UNM Economics Building HVAC and Controls
Results
Albuquerque, NM 87131

H341--HVAC Test and Balance Needed for New Mexico VA Health Care System
Post-Bid
Albuquerque, NM

UNM FM Utilities New Trane Chiller Install
Results
$332,910 est. value
Albuquerque, NM 87131

UVC Units
Post-Bid
Albuquerque, NM

New Lomas Chiller Electrical Connection
Results
Albuquerque, NM 87131

Air Duct Cleaning Services
Post-Bid
Albuquerque, NM

Lomas Tower 5 Chiller Project
Results
Albuquerque, NM

HVAC Equipment and Supplies
Post-Bid
Albuquerque, NM

UNM FM Utilities Cooling Tower #5 Install
Post-Bid
Albuquerque, NM

HVAC and Mechanical Products
Term Contract
Post-Bid

Design-Build For HVAC Repair, Golf Course at Cannon AFB, NM
Post-Bid
$500,000 to $1,000,000 est. value

Reported 04/03/2020 12:00 AM
Project Title

S201--501- Kitchen Hood Cleaning

Physical Address View project details and contacts
City, State (County) Albuquerque, NM 87108   (Bernalillo County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Request for Quotations
Bids Due View project details and contacts
Estimated Value
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Contracting intends to solicit services for the following under 36C25820Q0162 for Kitchen Hood cleaning at the: New Mexico VA Health Care System (NMVAHCS) 501 San Pedro Dr SE Albuquerque, NM 87108 There is an immediate need to provide cleaning and maintenance to main kitchen exhaust hoods located in the Main Hospital and the Canteen. The Contractor will clean all exhaust systems according to the standards set forth by the International Kitchen Exhaust Cleaning Association (IKECA) and maintain service cycles in compliance with the National Fire Protection Association (NFPA 96) recommendations. The Contractor will manually scrape, degrease and/or pressure wash all portions of all kitchen exhaust systems located at this facility. Locations are: Main Hospital Kitchen (Bldg. 41) Canteen Kitchen (Bldg. 2) Canteen Bistro (Bldg. 2) Canteen Snack Station (Bldg. 2) Kitchen exhaust cleaning services will include the interior and exterior of all grease hood canopies, fire protection system pipes, links and nozzles, hood plenums, duct collars, water wash troughs, including hood-to-floor drains, plus all horizontal and vertical ductwork leading to, and including, all kitchen exhaust fans and stacks. The 16 filters in Building 2 will be exchanged quarterly during the cleaning service. As part of the regular service, the Contractor will provide before-and-after digital photos of all exhaust cleaning work performed upon request.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents