Similar Projects
Valley Springs Middle School Mechanical Upgrade
Bidding
Arden, NC 28704

Removal and Replacement of Two (2) Hot Water Heaters
Bidding
Wilmington, NC

US Cellular Center Mechanical/HVAC Renovation
Post-Bid
Asheville, NC

J--Chiller Inspection and Maintenance
Post-Bid
Asheville, NC 28805

Steam Distribution System Replacement Phase IV-A
Results
Less than $2,000,000 est. value
Greensboro, NC

South Wilmington Street Center - Mechanical System Replacement
Results
Raleigh, NC

Boiler Service and Inspection
Term Contract
Post-Bid
Pembroke, NC

Boiler Replacement in Killian Building
Results
Less than $61,890 est. value
Flat Rock, NC

Upgrade Chiller Plant Fort Bragg, NC
Post-Bid
Fort Bragg, NC 28307

Ultrasoft Water Softener Unit
Results
Camp Lejeune, NC 28547

Hope Mills Library Boiler Replacement
Post-Bid
Hope Mills, NC 28348

Northern Wake Campus Exterior Hydronic Piping and Equipment Addition
Results
Raleigh, NC

Blue Ridge Community College Spearman Building Boiler 1 Replacement
Post-Bid
Flat Rock, NC 28731

North Buncombe Elementary School Boiler Replacement
Results
Less than $74,367 est. value
Weaverville, NC 28787

Reverse Osmosis System for 30 Locations
Post-Bid
NC

Reported 04/17/2020 12:00 AM
Project Title

Mechanical Repairs Bldg RR400 (18-0041)

Physical Address View project details and contacts
City, State (County) Camp Lejeune, NC 28547   (Onslow County)
Category(s) Single Trades
Sub-Category(s) Mechanical
Contracting Method Competitive Bids.
Project Status Request for Proposals (RFP)
Bids Due View project details and contacts
Estimated Value $1,000,000 to $5,000,000
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

The work includes the replacement of the existing two (2) air stacked chiller units with three (3) approximate 400 ton air-cooled chillers. The work also includes demolition and replacement of existing chiller enclosure with an aesthetic brick enclosure. Demo existing equipment pads and replace with properly sized pads for new equipment. Replace gravel mechanical yard with concrete yard. Provide temporary power for temporary/portable chiller. Repipe chilled water to provide isolation valves and a portable chiller tap for emergency situations. Configure controls and pumps to allow differential pumping and redundancy. Provide electrical upgrades to support new equipment. Replace the existing four (4) non-condensing hot water boilers, with new condensing hot water heating appliances. Replace LP gas lines and regulators in boiler room and incidental related work.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Packaged Water Chillers.
Division 42 - Process Heating, Cooling, and Drying Equipment, Process Chillers and Coolers.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents