Similar Projects
Parsons Unit Improvements Project
Renovation
Bidding
$173,000 est. value
UT

Bingham Creek Regional Park Phase 2
Post-Bid
Salt Lake City, UT

Construction Of New Baseball Dugouts
New Construction
Post-Bid
Tabiona, UT 84072

Oquirrh Hills Golf Course Pavilion
New Construction - 3,140 SF
Results
Tooele, UT 84074

Park Pavilion
Term Contract
Results
Less than $800,000 est. value
Murray, UT 84107

Press Box Buildings and Coaches Offices at Hunter High School
Construction
West Valley City, UT 84120

Nordic Valley Expansion
New Construction
Pending Verification
$6,500,000 est. value
Eden, UT

Clyde Rec Center Pickleball Courts Project
Post-Bid
Springville, UT

Steed Park Pickleball Design/Build
Results
Less than $350,000 est. value
Clearfield, UT 84015

RAC Shade Structure
Post-Bid
Salt Lake City, UT 84114

2020 Park Improvements
Results
Draper, UT

Dfcm Construction-Willard Bay State Park Day Use Pond Improvements-19074510
Results
Less than $375,000 est. value
Willard, UT

Bristlecone Pond Trail Engineering Services
New Construction, Addition
Results
Brian Head, UT 84719

RBG Herb Garden Kitchen
Results
$25,000 to $100,000 est. value
Salt Lake City, UT 84108

Parks Building Addition
Addition
Results
$150,000 to $200,000 est. value
Bluffdale, UT 84065

Last Updated 04/13/2021 11:21 AM
Project Title

Homestead Park Pavilion

Physical Address View project details and contacts
City, State (County) Riverton, UT 84065   (Salt Lake County)
Category(s) Entertainment/Recreation
Sub-Category(s) Misc. Recreational
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Remove and replace existing pavilion and concrete pad at Homestead Park, 13742 South 2200 West. Concrete pad is 25' x 25' and the new pavilion is to be close to the same size. Pavilion is to be all steel construction, 6" steel posts, similar in design as Steelworx HP-2424-SW style or acceptable substitute, see attached (which is a different size, but the style they want). Color to be determined. Demo and haul off existing concrete. New concrete pad is to be 4000psi, AA-AE, six bag mix, 5" thick placed on 4" of road base, compacted to 95% compaction. Concrete pad is to have an 18" x 18" #3 bar tied together or wire mesh mate overlapped at a minimum of one square and tied. Bar or wire mesh is to be from edge to edge and shall be placed in the middle of the concrete. Done to APWA 03 30 04 specification.

Details

Misc. Recreational, Renovation.
Division 03 - Concrete.
Division 13 - Special Construction.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents