Similar Projects
Justice Center Tunnel Flooring Replacement
Post-Bid
Fayetteville, GA 30214

GGC Building F- Gym Floor Replacement
Post-Bid
Lawrenceville, GA 30043

Replace Gym Flooring at an Elementary School
Results
Saint Simons Island, GA 31522

Detention Center Flooring
Results
Dahlonega, GA 30533

72--Epoxy Garage Flooring
Post-Bid
Fort Benning, GA

Sheriff`s Administration Building Flooring Replacement
Results
Augusta, GA 30901

Demand Services Contract for Flooring and Carpet On-Call Contractors
Post-Bid
Gainesville, GA

Lou Walker Senior Center Locker Room Floor Replacement
Results
Lithonia, GA

Luxury Vinyl Flooring Installation
Post-Bid
Cedartown, GA

Remove Carpet and Replace Tile
Results
Cumming, GA 30040

LVT and Carpet Replacement Installation at Marietta Fire Department Station #51
Post-Bid
Marietta, GA 30061

Fire Station 10 Flooring and Painting
Results
Fayetteville, GA 30215

Flooring Improvements To The Deed Room
Post-Bid
Sandersville, GA

MXG Carpet
Results
Moody AFB, GA 31699

Acworth Municipal Detention Center Flooring Contract
Post-Bid
Acworth, GA 30101

Reported 06/18/2020 12:00 AM
Project Title

78--Gym Flooring

Physical Address View project details and contacts
City, State (County) Savannah, GA 31409   (Chatham County)
Category(s) Single Trades
Sub-Category(s) Flooring
Contracting Method Competitive Bids.
Project Status Request for Quotations
Bids Due View project details and contacts
Estimated Value
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

The MICC End User requires the following items, Brand Name or Equal, to the following: LI 001: 1” (25.2mm) Rolled Rubber Gym Flooring Color: Smoke (Preferred) Must have a 13.2mm dual laminated vulcanized rubber combined with a 12mm shockpad THICKNESS: 1.0” Warranty must be at least 20 Years PERFORMANCE CRITERIA (Tensile Strength - ASTM D 412 - >200 PSI) (Flexibility 1/4” Mandrel ASTM F 137 Pass) (Thermal Conductivity ASTM C 518 2.1 Btu-in/h-ft-F) (Static Load Limit ASTM F 970 @ 250PS 0.004” Pass) (Coefficient of Friction ASTM D 2047 >0.9) (V.O.C. Compliant ASTM D 5116 Pass:Yes) (Abrasion Resistance ASTM D 3389 / EN 649 <1g, 1000 cycle) (Resistance to Heat ASTM F 1514 ? E <8.0) (Pill Test ASTM D 2859 Pass) (Vertical Deflection / Deformation ASTM F 2772 1.6mm) (Surface Effect Slip Resistance ASTM F 2772 92) (Ball Rebound ASTM F 2772 100%) (Force Reduction ASTM F 2772 40%) Sheet Dimension: 4’ width by Minimum length of 25 LF), 8895, EA; LI 002: Water Jet Cut: Rubber In-Lay Platforms w/ Custom Logos Custom Ranger Seal 5'-6 1/2" x 6'-8 3/8" Must be Water-Jet cut. Must be flushed with gym flooring. See DUI Attachment for design, 1, EA; LI 003: 12mm Shock Pad Structure----Our shock pad has been adopted proportion 4:6 and three-layer composite technology. Compared with one-time foaming process product, one-time foaming product is easily deformed, and elasticity lost too quickly make it difficult to restore elasticity after long-term use. •Material-The perfect combination of new environmental protection resin and rubber foam, rubber has a strong tensile strength and softness, which ensure the strong elasticity and softness brings sense of comfort at the same time. The UV resistant film brings the long service life for the shock pad who is more environmentally friendly, no odor. •Cutting technology---Cutting grooves vertically and horizontally with holes to make sure water drainage in four directions, and installation more even. •Tensile strength---Three-layer structure and characteristics of rubber makes the shock pad with the strong tensile strength, which will protect the product from deformation and damage during the installation. Tensile strength of one-time forming process product is poor. Structure Three layers Material Easy to handle Thickness 12mm Length Tailored for pitch Width 1.5 meter Installation guide Yes Drainage Good Flame retardant Yes, 645, EA; LI 004: 4-gallon E-Grip Adhesive 1.Easy to trowel and apply 2.Solvent Free 3.No mixing required 4.Excellent curing cycle 5.Very low odor 6.Non-flammable, 57, EA; LI 005: UltraTile Reducer 1" x 4" x 48" UltraTile Reducers enable a smooth, beautiful transition to other floor coverings, and are available in matching colors to the UltraTiles. 1. Shock Attenuation (ASTM F1292) – 2-1/2” meets 5’ critical fall height. To achieve 6’, 8’ or 10’ critical fall heights, install a 2-1/4” Ecore polyfoam pad under the 2-1/2” tiles. a. Gmax – Less than 200. b. Head Injury Criteria – Less than 1000. 2. Flammability (ASTM D2859) – Pass. 3. Tensile Strength (ASTM D412) – 180 lbs/in2 min. 4. Water Permeability Rate: 0.034 cm/sec. 5. Accessibility: Comply with requirements of ASTM F1951-08 – Pass. 6. Lead Content: (US EPA Method 3052: 1996) – Pass. 7. Void Volume: 42% min 2-1/2”. 50% min 4-14”. 8. Coefficient of Thermal Expansion: .0011 in/ft/º F. 9. Wear Surface Density: 70 lbs/cu ft min. 10. Abrasion Testing (ASTM D3389): Less than 0.010” lost or less than 1 g lost. 11. Elongation At Break (ASTM D412): 70% min. Designed with a patented “Ultra” wear layer to provide unlimited design options, GSFloor UltraTiles offer a new brand of visual excitement to any fitness facility or club interior. UltraTile now has 16 standard designs, chosen specifically to coordinate with fitness equipment as well as other flooring options. By featuring a pedestal underside, these tiles help prevent cable clutter by routing fitness equipment wiring beneath the surface!, 11, EA; LI 006: Water Jet Cut: Rubber In-Lay Platforms w/ Custom Logos 4' x 6' Custom In-Lay 2' x 6' Black Drop Zones Must be Water-Jet cut. Must be flushed with gym flooring. Will be placed in front of 32 racks. See Scroll attachment for design, 32, EA; LI 007: Floor Installation, 1, EA; LI 008: 4' x 6' Custom In-Lay 2' x 6' Black Drop Zones Installation, 32, EA; LI 009: Custom Ranger Seal 5'-6 1/2" x 6'-8 3/8" Installation, 1, EA; LI 010: Shipping to BLDG 724 248 Stephen Douglas St Hunter Army Airfield, GA 31409, 1, EA;

Details

Division 09 - Finishes, Flooring.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents