Similar Projects
Last Updated | 10/01/2022 05:31 PM |
Project Title | New Data Center Project |
Physical Address | View project details and contacts |
City, State (County) | Bolivia, NC 28422 (Brunswick County) |
Category(s) | Commercial, Education, Heavy and Highway |
Sub-Category(s) | Communication Building, Middle/Senior High School, Site Development |
Contracting Method | Competitive Bids |
Project Status | Bidding, Construction start expected December 2022 |
Bids Due | View project details and contacts |
Estimated Value | $1,500,000 [brand] Estimate |
Plans Available from | Agency's Affiliate |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | New Data Center Project Questions submitted to dbair@bcswan.net (Reference RFP # in subject line) 9/26/2022 Provide Response to Questions 9/27/2022 Brunswick County Schools reserves the unqualified right to reject any and all offers when such rejection is deemed to be in the best interest of Brunswick County Schools. This project is an integrated turnkey data center solution and shall include the following: o Purchase of Cisco network, security and server equipment for the Data Center. Scope of project is to upgrade all Cisco equipment and to purchase software and hardware support for five years of coverage. Full purchase list will be provided at the Pre-Bid Meeting. Engineering professional services for configuration and installation assistance of the Cisco equipment will be negotiated separately once a solution provider is awarded the project. o 20KVA UPS 480/208/120 with isolation transformer, 20KVA redundant module, external maintenance bypass with SKRU, and a communication card. UPS be manufactured by the same manufacture as the rack solution and HVAC to maintain match and finish. o 3 rack integrated solution with supply air plenum for under the cabinets and return air plenum for top of the cabinets. All plenums must be manufactured by the same manufacture as the server cabinets, UPS and HVAC and have the same fit and finish. o Quantity (2) 5 Ton downflow (No Exceptions) 460 V precision cooling units with controls that can be networked together, 460V high ambient, and coated condensers. HVAC unit shall have integrated electrical panel and fire suppression. HVAC Units shall be manufactured by the same manufacture as UPS, Server Racks and under the rack supply plenum and top of the rack return plenum to maintain same fit and finish. o Quantity (6) 3 phase rack mount PDUs with L21-30 input with C13-C19 Combination. All PDUs must be metered and controlled at a receptacle level. o SNMP Monitoring software. o Integrated fire suppression. o Quantity (1) 150 KW 480 Volt Generator with 72 hour base tank LSI breaker, sound aluminum enclosure 75 DBA at 23', tropicalized coated alternator, Communications Card and Matching 3 pole standard transition ATS, NFPA 110 system in a NEMA 1 Enclosure. |
||||||||||||||||||||||||||||||||||||||
Details |
|
||||||||||||||||||||||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||||||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||||||||||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |