Similar Projects
Last Updated | 03/15/2022 10:10 AM |
Project Title | C1da-- Proj # 402-21-709 Replace Elevators Building 200 & 200E |
Physical Address | View project details and contacts |
City, State (County) | Augusta, Togus, ME 04330 (Kennebec County) |
Category(s) | Professional Services |
Sub-Category(s) | Architectural, Engineering |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | $500,000 to $1,000,000 |
Plans Available from | Federal Agency |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | Complete construction design package including plans and specifications to evaluate and replace if required all elevator equipment (Elevators 1, 2, 3, 4, 5) in buildings 200 and 200E but excludes service elevator #6 in 200E which was replaced in 2018. This project does not include any modifications to the existing size of the hoist ways. Mechanical equipment to be evaluated and possibly replaced will include but is not limited to elevator guides, steel wire ropes, rollers, pulleys, control cabinets, motor and drive and drive equipment and any other equipment as determined by the elevator equipment design firm. Cosmetic improvements will include upgrading all finishes in each car elevator which includes flooring, sides, ceilings including new LED lighting as well as ADA compliant elevator call buttons/car locator inside and outside of the car. In addition to the above work, the elevator design firm will evaluate whether additional elevators can be placed on emergency power (equipment branch). The goal is to have at least one additional elevator on emergency power. Also, part of this scope of work is an evaluation of the existing elevator recall system, firefighter s operation, and elevator specific fire alarm system and sprinkler system upgrades as required by current code. In addition, emergency 2-way communication from the elevator will be evaluated for compliance with current code, a new medical emergency bypass system with priority keys located inside of the cabs and outside the elevators in required locations and all required priority switches. Currently two elevators (number 2 & number 6) are integrated into a robot transport system (Aethon- TUG) which has interfaces with the elevator control panels to allow the robots to command an elevator. |
Details | Architectural, New Construction. |
Bidder's List | View project details and contacts |
Prospective Bidders | View project details and contacts |
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |