Similar Projects
Last Updated | 07/05/2023 05:13 PM |
Project Title | Generator Maintenance |
Physical Address | View project details and contacts |
City, State (County) | Holloman Air Force Base, NM 88330 (Otero County) |
Category(s) | Single Trades |
Sub-Category(s) | Service/Term Contracts |
Contracting Method | Competitive Bids |
Project Status | Sub-Bidding, Construction start expected August 2023 |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | Agency's Affiliate |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | This pre-solicitation notice is to annouce the upcoming solicitation of Generator Maintenance services at Holloman AFB, NM, which should be posted in the near future. This contract is for a period of five (5) years consisting of one (1) base year and four (4) option years. Estimated award date: 1 June 2023. The following is a summary of the service requirements: There are approximately 10 generators supporting three organizations and the generators are located in multiple areas around the base. The Contractor shall provide all personnel/labor, equipment, materials/supplies, transportation, tools, supervision, and any other non-personal services necessary to perform preventive maintenance generator service. Services include, but not limited to, load testing for the electrical backup generator & automatic transfer switches, providing inspection checklist, load test report, accepted service reports and any other maintenance accomplished. The Contractor shall inform the Government when generators surpass 90 percent of their service life (9000 hours) enabling coordination for overhaul/replacement purchases to avoid negative mission impact due to a down generator. The contractor shall provide the Government reports of any additional work that will be required from discovery during routine inspections and maintenance. The Government will be responsible for additional cost outside the scope of the requirement. The Contractor will make every effort to accomplish additional required work during the next scheduled inspection in effort to minimize cost to the government. Inspections (monthly, semi-annual, etc.) will be conducted in accordance with each generators' service manual. Below are the manufacturers and models for the generators and automatic transfer switchs: Manufacturer: Onan; Model: Gen Set; Product Models: 35DSFAA; 125DSGAB; DSGAB-1714141; DSGAB-1718799 Manufacturer: Cummins; Model: Gen Set; Product Models: C60 D6C; DQHAB-5787808; KTA-38-G2; C150 D6D Automatic transfer switch description: Item: 1) Onan OTPCC; 2) Pole; 3) Phases 120/208 VAC switches; 4) Bypass,PwrCmd,225Amp, 4-poles, 3 Phase 208 VAC; 5) Merlin Gerin (Compact NSJ600J) 240/600/a; 6) Cummins OTPC Transfer Switch; Qty: 1) Three (3); 2) Three (3); 3) Three (3); 4) One (1); 5) One (1); 6) Two (2) |
||||||
Details |
|
||||||
Bidder's List | View project details and contacts | ||||||
Prospective Bidders | View project details and contacts | ||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |