Reported | 09/10/2020 12:00 AM |
Project Title | Uninterrupted Power Supply (UPS) and Batteries |
Physical Address | View project details and contacts |
City, State (County) | Sparta, WI 54656 (Monroe County) |
Category(s) | Single Trades |
Sub-Category(s) | Electric |
Contracting Method | Competitive Bids. |
Project Status | Request for Quotations |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | Federal Agency |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | FOB Destination shall be Fort McCoy, WI 54656 The MICC End User requires the following items, Brand Name or Equal, to the following: LI 001: (Equal to or better than) MITSUBISHI 1100 40K ON LINE TOWER 208Y120V IN/OUT - Mitsubishi Diamond Plus 1100A Series 40KVA/36KW double-conversion UPS - Three-phase 208/120V in and out - Transformerless - 5-slot Chassis consists of (4) 10KVA/9KW Power Modules - Static Switch and Controller - Set up for external batteries - Scalable to 50KVA or 40KVA N+1 - Hot Swappable Modules - Bottom or side cable entry - Castors and leveling feet included - Efficiency is 93% Integration and Installation into existing power distribution system Old UPS system removal and disposal Removal and disposal of second UPS in separate area. Parts & Labor warranty Parts coverage for batteries Must hold installation certification if required by manufacturer, 1, EA; LI 002: (Equal to or better than) (BC29-24E205-040B3-175) - BC29 Battery Cabinet with (24) Enersys 205WPC Batteries - 175A breaker - 10 minutes runtime @ 40KVA/36KW load - Castors - DC installation cables Integration and Installation into existing power distribution system, 1, EA; LI 003: (Equal to or better than) (CBL-1100-050-DC-1) - UPS to Battery Cabinet / 1 Cabinet, 50kVA, - Cable Size 4/0 - DLO, 111" long. - DC cables for adjacent battery cabinet to UPS. Integration and Installation into existing power distribution system, 1, EA; LI 004: (Equal to or better than) (UD100106-50S3KNN0) - Maintenance Bypass Switch, 3-breaker. - 208V, 50KVA, Includes - Mechanical Kirk Keys - Wallmount kit Integration and Installation into existing power distribution system, 1, EA; LI 005: (Equal to or better than) (UD100350G01) - Diamond Plus 1100 I/O board with NetCom Communications Integration and Installation into existing power distribution system, 1, EA; LI 006: 12 VDC 80 AH Flame retardant battery (UPS12-300MR), 136, EA; LI 007: 12 VDC 7 AH Flame retardant battery (GP1272FRF2), 220, EA; LI 008: 12 VDC 17 AH Flame retardant battery (GP12170BFR), 4, EA; LI 009: 12 VDC 5.5 AH Flame retardant battery (HR1221FRF2), 168, EA; LI 010: 12 VDC 33 AH Flame retardant battery (HR12150WFR), 15, EA; |
||
Details |
|
||
Bidder's List | View project details and contacts | ||
Prospective Bidders | View project details and contacts | ||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |