Similar Projects
Watermain Replacement - East 232 and Williams Avenue
Bidding
Euclid, OH 44123

Watermain Replacement - Drakefield Avenue and East 266th Street
Bidding
Euclid, OH 44123

Sewer and Water Maintenance Appurtenances
Term Contract
Post-Bid
Less than $50,000 est. value
Lakewood, OH

2020 A-Water Main Renewal
Post-Bid
Cleveland, OH 44114

Superior Road Express Main Replacement Project
Results
Cleveland, OH

Fischer Road Watermain Replacement
Results
Less than $190,000 est. value
Lakewood, OH

2020 Water Main Replacement and Pavement Resurfacing
Bidding
Less than $642,500 est. value
Cleveland, OH 44126

B-Water Main Renewal
Post-Bid
Cleveland, OH 44114

River and West Street Improvements
Results
Chagrin Falls, OH

Hollywood Avenue Water Main Replacement
Bidding
$70,000 est. value
Maple Heights, OH 44137

Vitrified Clay and PVC Pipe
Post-Bid
Cleveland, OH 44114

Service Fittings
Results
Cleveland, OH

4610--VHA Mar Cor Reverse Osmosis Water Purification BNOE | Sources Sought | 36U10120Q0029
Post-Bid

Liner Pipe
Term Contract
Results

2020-C Water Main Renewal
Post-Bid
Cleveland, OH 44114

Reported 03/09/2019 12:00 AM
Project Title

N--541-19-2-5796-1243 New Retherm Chilled Water Piping (VA-19-00036004) New Retherm Chilled Water Piping

Physical Address View project details and contacts
City, State (County) Cleveland, OH   (Cuyahoga County)
Category(s) Sewer and Water
Sub-Category(s) Water Lines
Contracting Method Competitive Bids.
Project Status Request for Quotations
Bids Due View project details and contacts
Estimated Value
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description Insulate all new chilled water copper piping in main kitchen with 1 fiberglass wall pipe insulation. Pipe fittings such as 90 s and Tees shall be Zeston or equal and taped for a proper vapor barrier. Insulate 6-FT washing machine hoses with removable ¾ wall flexible Armor flex insulation, field verify. Exposed fiberglass pipe insulation, valves, strainers and circuit setters shall be covered with a plastic outer barrier for housekeeping purposes. Exposed plastic outer barrier shall be rated for a food preparation area. Exposed Armor flex shall have an outer plastic or painted sealed rated for food preparation area.
Details
Division 33 - Utilities, Instrumentation and Control for Utilities, Water Utilities, Water Utility Distribution Piping, Water Utility Distribution Equipment, Disinfecting of Water Utility Distribution, Water Utility Storage Tanks.
Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents