Similar Projects
Doors Security Corrections
Design
$2,000,000 to $5,000,000 est. value
Chicago, IL 60612

Auditorium Audio-Visual Upgrades at Harlem High School
Alteration
Bidding
Machesney Park, IL 61115

CPS Von Steuben Genetec Camera
Term Contract
Bidding
Chicago, IL

Sports Complex Wi-Fi and Security Cameras
Renovation
Post-Bid
Rantoul, IL 61866

Wide Area Network
Post-Bid
Washington, DC

Network & Access Point Wiring
Results
Grayslake, Vernon Hills, IL 60030

Adams Field Scoreboard Replacement at Deerfield HS
Results
Deerfield, IL 60015

District Access Door Control System for the Transition Center Tenant Buildout
Alteration
Bidding
Burr Ridge, IL 60527

Video Event GPS Recorders
Post-Bid
Schaumburg, IL 60193

Elgin Community College - Arts Center Audio System Upgrades
Results
Elgin, IL 60123

Replacement Phone System
Post-Bid
Columbia, IL 62236

Robinson Transportation Building Perimeter Fencing
Renovation
Results
Robinson, IL 62454

43 AMOG Conference Room A/V Upgrade
Post-Bid
IL

Model Field Office Fiber Installation
Results
Chicago, IL 60661

Fire Station Alerting System
Post-Bid
Moline, IL 61265

Reported 05/26/2021 12:00 AM
Project Title

Upgrades to Direct Digital Control System (DDCS)

Physical Address View project details and contacts
City, State (County) Rock Island, IL   (Rock Island County)
Category(s) Single Trades
Sub-Category(s) Security/Communications
Contracting Method Competitive Bids.
Project Status Request for Quotations
Bids Due View project details and contacts
Estimated Value
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Relative Humidity Sensors/Transmitters: a. Provide sensor as solid state, resistance type relative humidity sensor of the Bulk Polymer Design. Provide the sensor element as washable and resists surface contaminations. b. Equip humidity transmitter with non-interactive span and zero adjustments, a 2- wire isolated loop powered, 4-20ma, 0-10.0 VDC linear proportional output. c. The humidity transmitter in accordance with the following overall accuracy including lead loss and A to D conversion. (1) Room Type Sensor: plus or minus 2 percent RH (2) Duct Type Sensor: plus or minus 2 percent RH d. Install outside air relative humidity sensors in a rain proof, perforated cover. Install the transmitter in a NEMA 3R enclosure with conduit fittings and stainlesssteel bushings. e. Provide a single point humidity calibrator, if required, for field calibration. Transmitters to ship factory pre-calibrated. f. Construct duct type sensing probes of 304 stainless steel and equipped with a neoprene grommet, bushings, and a mounting bracket.

Details

Division 27 - Communications, Common Work Results for Communications.
Division 28 - Electronic Safety and Security, Common Work Results for Electronic Safety and Security.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents