Similar Projects
Last Updated | 06/16/2022 03:05 AM |
Project Title | Pre-Event Emergency Signal Repair and Replacement Operations |
Physical Address | View project details and contacts |
City, State (County) | FL (Miami-Dade County) |
Category(s) | Heavy and Highway |
Sub-Category(s) | Traffic Signalization |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | $5,000 |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | Emergency (Pre-Event) Contract to provide Sign Repair and Replacement Operations, including permanent repairs, pursuant to a Governor's and/or President's Declaration of a State of Emergency in Miami-Dade County within District Six. The contractor shall provide all labor, material, and equipment, required to complete the services described in Exhibit A - Scope of Services, including any TTC, Temporary Traffic Control, Mobilization and Demobilization costs Section 0001 Emer.delineator/attenuator/sign Repr(Ea) 0630- 2- 11 Conduit, Furnish & Install, Open Trench Lf 100.000 0630- 2- 12 Conduit, Furnish & Install, Directional Bore Lf 100.000 0630- 2- 14 Conduit, Furnish & Install, Aboveground Lf 100.000 0630- 2- 15 Conduit, Furnish & Install, Bridge Mount Lf 100.000 0632- 7- 2 Signal Cable- Repair/replace/other, Furnish & Install Lf 100.000 0634- 4-142 Span Wire Assembly, F&i, Single Point, Diagonal Pi 1.000 0634- 4-152 Span Wire Assembly, F&i, Two Point, Diagonal Pi 1.000 0635- 2- 11 Pull & Splice Box, F&i, 13" X 24" Cover Size Ea 1.000 0635- 2- 12 Pull & Splice Box, F&i, 24" X 36" Cover Size Ea 1.000 0639- 1-111 Electrical Power Service, F&i, Overhead, Meter Furnished by Power Company as 1.000 0639- 1-112 Electrical Power Service, F&i, Overhead Meter Purchased by Contractor From Power Company as 1.000 0639- 1-113 Electrical Power Service, F&i, Overhead Meter Not Required as 1.000 0639- 1-121 Electrical Power Service, F&i, Underground, Meterfurnished by Power Companyas 1.000 0639- 1-122 Electrical Power Service, F&i, Underground, Meterpurchased by Contractoras 1.000 0639- 1-123 Electrical Power Service, F&i, Underground, Meter Notrequiredas 1.000 0641- 2- 12 Prestressed Concrete Pole, F&i, Type P-ii Service Pole Ea 1.000 0641- 2- 15 Prestressed Concrete Pole, F&i, Type P-v Ea 1.000 0670- 4- 1 Intersection Control Beacon Controller Assembly,furnish & Install as 1.000 0700- 1- 11 Single Post Sign, F&i Ground Mount, Up to 12 Sf as 489.000 0700- 1- 12 Single Post Sign, F&i Ground Mount, 12-20 Sf as 489.000 0700- 1- 13 Single Post Sign, F&i Ground Mount, 21-30 Sf as 489.000 0700- 1- 14 Single Post Sign, F&i Ground Mount, 31+ Sf as 125.000 0700- 1- 21 Single Post Sign, F&i Barrier Mount Index 11871/700-013 Up to 12 Sf as 1.000 0700- 1- 22 Single Post Sign, F&i Barrier Mount Index 11871/700-013, 12- 20 Sf as 1.000 0700- 1- 31 Single Post Sign, F&i Bridge Mount Index 11870/700-012, Up to 12 Sf as 25.000 0700- 1- 32 Single Post Sign, F&i Bridge Mount Index 11870/700-012, 12-20sfas 25.000 0700- 1- 80 Single Post Sign, Repair as 300.000 0700- 1- 87 Single Post Sign, Repair- Replace Post, Use Existing Signpanelas 200.000 0700- 2- 11 Multi- Post Sign, F&i Ground Mount, Up to 12 Sf as 10.000 0700- 2- 12 Multi- Post Sign, F&i Ground Mount, 12-20 Sf as 10.000 0700- 2- 13 Multi- Post Sign, F&i Ground Mount, 21-30 Sf as 10.000 0700- 2- 14 Multi- Post Sign, F&i Ground Mount, 31-50 Sf as 10.000 0700- 2- 15 Multi- Post Sign, F&i Ground Mount, 51-100 Sf as 11.000 0700- 2- 16 Multi- Post Sign, F&i Ground Mount, 101-200 Sf as 22.000 0700- 2- 17 Multi- Post Sign, F&i Ground Mount, 201-300 Sf as 22.000 0700- 2- 18 Multi- Post Sign, F&i Ground Mount, 301-400 Sf as 5.000 0700- 2- 50 Multi- Post Sign, Ground Mount, Relocate as 1.000 0700- 3-101 Sign Panel, Furnish & Install Ground Mount, Up to 12 Sf Ea 473.000 0700- 3-102 Sign Panel, Furnish & Install Ground Mount, 12-20 Sf Ea 473.000 0700- 3-103 Sign Panel, Furnish & Install Ground Mount, 21-30 Sf Ea 473.000 0700- 3-104 Sign Panel, Furnish & Install Ground Mount, 31-50 Sf Ea 158.000 0700- 3-105 Sign Panel, Furnish & Install Ground Mount, 51-100 Sf Ea 63.000 0700- 3-106 Sign Panel, Furnish & Install Ground Mount, 101-200 Sf Ea 17.000 0700- 3-107 Sign Panel, Furnish & Install Ground Mount, 201-300 Sf Ea 17.000 0700- 3-108 Sign Panel, Furnish & Install Ground Mount, 301-400 Sf Ea 8.000 0700- 3-109 Sign Panel, Furnish & Install Ground Mount, 401-500 Sf Ea 5.000 0700- 3-201 Sign Panel, Furnish & Install Overhead Mount, Up to 12 Sf Ea 5.000 0700- 3-202 Sign Panel, Furnish & Install Overhead Mount, 12-20 Sf Ea 10.000 0700- 3-203 Sign Panel, Furnish & Install Overhead Mount, 21-30 Sf Ea 16.000 0700- 3-204 Sign Panel, Furnish & Install Overhead Mount, 31-50 Sf Ea 32.000 0700- 3-205 Sign Panel, Furnish & Install Overhead Mount, 51-100 Sf Ea 16.000 0700- 3-206 Sign Panel, Furnish & Install Overhead Mount, 101-200 Sf Ea 47.000 0700- 3-207 Sign Panel, Furnish & Install Overhead Mount, 201-300 Sf Ea 47.000 0700- 3-208 Sign Panel, Furnish & Install Overhead Mount, 301-400 Sf Ea 31.000 0700- 3-209 Sign Panel, Furnish & Install Overhead Mount, 401-500 Sf Ea 5.000 0700- 3-210 Sign Panel, Furnish & Install Overhead Mount, 501-600 Sf Ea 5.000 0700- 3-211 Sign Panel, Furnish & Install Overhead Mount, 601 Sf Andgreaterea 5.000 0700- 3-301 Sign Panel, Furnish & Install Single Post Bridge Mountindex 11870/700-012, Up to 12 Sf Ea 10.000 0700- 3-302 Sign Panel, Furnish & Install Single Post Bridge Mountindex 11870/700-012, 12-20 Sf Ea 10.000 0700- 3-401 Sign Panel, Install, Up to 12 Sf Ea 165.000 0700- 3-402 Sign Panel, Install, 12-20 Sf Ea 165.000 0700- 3-403 Sign Panel, Install, 21-30 Sf Ea 165.000 0700- 3-404 Sign Panel, Install, 31-50 Sf Ea 68.000 0700- 3-405 Sign Panel, Install, 51-100 Sf Ea 19.000 0700- 3-406 Sign Panel, Install, 101-200 Sf Ea 7.000 0700- 3-407 Sign Panel, Install, 201-300 Sf Ea 1.000 0700- 3-408 Sign Panel, Install, 301-400 Sf Ea 1.000 0700- 4-111 Overhead Static Sign Structure, Furnish & Install,cantilever, Up to 20 Ftea 8.000 0700- 4-112 Overhead Static Sign Structure, Furnish & Install,cantilever, 21-30 Ftea 8.000 0700- 4-113 Overhead Static Sign Structure, Furnish & Install,cantilever, 31-40 Ftea 8.000 0700- 4-114 Overhead Static Sign Structure, Furnish & Install,cantilever, 41-50 Ftea 5.000 0700- 4-121 Overhead Static Sign Structure, Furnish & Install, Span, Up to 20 Ftea 5.000 0700- 4-122 Overhead Static Sign Structure, Furnish & Install, Span,21-30 Ftea 5.000 0700- 5- 11 Internally Illuminated Sign, Furnish & Install Groundmount, Up to 12 Sfea 1.000 0700- 5- 21 Internally Illuminated Sign, Furnish & Install Overhead Mount, Up to 12 Sf Ea 5.000 0700- 5- 22 Internally Illuminated Sign, Furnish & Install, Overhead Mount, 12-18 Sf Ea 5.000 0700- 11-121 Electronic Display Sign, Furnish & Install Ground Mountac Powered, Electronic Regulatory Sign, Up to 12 Sf As 1.000 0700- 11-321 Electronic Display Sign, Furnish & Install Overhead Mount- Ac Powered, Regulatory Sign, Up to 12 Sf as 1.000 0700- 12- 11 Sign Beacon, F&i Ground Mount- Ac Powered, One Beacon as 1.000 0700- 12- 12 Sign Beacon, F&i Ground Mount- Ac Powered, Two Beacon as 1.000 0700- 12- 21 Sign Beacon, F&i Ground Mount- Solar Powered, One Beacon as 1.000 0700- 12- 22 Sign Beacon, F&i Ground Mount- Solar Powered, Two Beacons as 1.000 0700- 12- 31 Sign Beacon, F&i Overhead Mount, One Beacon as 1.000 0700- 12- 32 Sign Beacon, F&i Overhead Mount, Two Beacons as 1.000 0700- 12- 60 Sign Beacon, Remove Beacon- Sign to Remain as 1.000 0705- 10- 1 Object Marker, Type 1 Ea 50.000 0705- 10- 2 Object Marker, Type 2 Ea 50.000 0705- 10- 3 Object Marker, Type 3 Ea 50.000 0705- 11- 1 Delineator, Flexible Tubular Ea 100.000 0705- 11- 2 Delineator, Non-flexible Ea 100.000 E700- 46- 32 Repair Existing Sign (Multi Post) as 39.000 |
||
Details |
|
||
Bidder's List | View project details and contacts | ||
Prospective Bidders | View project details and contacts | ||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |