Similar Projects
Electric Car Charging Station
Design
Rutland, VT 05701

Repair/Upgrade Base Electrical Distribution System - Vermont Air National Guard Base
Bidding
$1,000,000 to $5,000,000 est. value
South Burlington, VT

Solar Electric Power Project
Alteration
Bidding
Woodstock, VT

Portable Generators and Light Poles
Post-Bid
Montpelier, VT

Fairbanks Museum And Planetarium - Electrical Grid And Weather Forecasting Resiliency
Post-Bid
$330,000 est. value
Saint Johnsbury, VT 05819

Group-Net-Metered Photovoltaic Electricity Generation
Results
Bolton, VT

NSL Replace the Electrical Conduits
Results
$250,000 to $500,000 est. value
Springfield, VT

Town and Community Solar PV Project
Post-Bid
Hinesburg, VT

Z--Tiered Evaluation Pre-Solicitation Notice White River Junction Replace Underground Utilities Construction Project
Results
$5,000,000 to $10,000,000 est. value
White River Jct, White River Junction, VT 05009

Generator Replacement - Castleton Elementary School
Post-Bid
Bomoseen, VT 05732

On-Call Electrical Services
Term Contract
Results
Bennington, VT 05201

Lyndon Town School Generator Power System
Post-Bid
Lyndon, VT

EV Charging Station
Results
Richmond, VT 05477

2020 Emergency Generator Project
Post-Bid
Norwich, VT

Generator for 4A Pump Station
Results
Castleton, VT 05735

Reported 05/21/2021 12:00 AM
Project Title

K041--Transformer Cooling Fans Installation In Building 31 Va Medical Center White River Junction, Vt

Physical Address View project details and contacts
City, State (County) Hartford, White River Jct, VT 05009   (Windsor County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Accepting Letters of Interest
Bids Due View project details and contacts
Estimated Value
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Transformer Cooling Fans Installation in Building 31. This work will furnish and install cooling fans on the two transformers serving Building 31. These fans will increase the capacity of each transformer from 750 KVA to 1000 KVA. The work includes but is not limited to: six (6) 120 VAC cooling fans with mounting brackets; two (2) transformer temperature monitors and controllers; two (2) control power transformers; SIS wiring; six (6) insulated thermocouples; and miscellaneous items

Details

Division 26 - Electrical.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents