Similar Projects
Last Updated | 04/03/2019 06:02 AM |
Project Title | Traffic OPS Improvement |
Physical Address | View project details and contacts |
City, State (County) | (Brevard, Flagler, Lake, Marion, Orange, Osceola, Seminole, Sumter, Volusia Counties) |
Category(s) | Heavy and Highway |
Sub-Category(s) | Traffic Signalization |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | $500,000 |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | Work Document driven quick response contract for installing traffic operational improvements including new or modifying existing turn lanes, median modifications, concrete (curb, gutter and sidewalks), milling, removal of flexible pavement, asphalt, sodding, loop assemblies, and pedestrian feature installation. Section 0001 Roadway 0102- 14- Traffic Control Officer Hr 100.000 0102- 60- Work Zone Sign Ed 5,000.000 0102- 71- 13 Temporary Barrier, f&i, Low Profile, Concrete Lf 100.000 0102- 74- 1 Channelizing Device- Types i, Ii, Di, Vp, Drum, Or Lcd Ed 10,000.000 0102- 76- Arrow Board / Advance Warning Arrow Panel Ed 400.000 0102- 99- Portable Changeable Message Sign, Temporary Ed 100.000 0104- 10- 3 Sediment Barrier Lf 2,000.000 0104- 18- Inlet Protection System Ea 10.000 0110- 2- 1 Clearing & Grubbing (Push Button Contract) Ac 5.000 0110- 4- 10 Removal Of Existing Concrete Sy 1,000.000 0120- 1- Regular Excavation Cy 1,000.000 0120- 2- 2 Borrow Excavation, Truck Measure Cy 1,000.000 0160- 4- Type b Stabilization Sy 2,000.000 0162- 1- 11 Prepared Soil Layer, Finish Soil Layer, 6" Sy 2,000.000 0285-709- Optional Base, Base Group 09 Sy 2,000.000 0285-710- Optional Base, Base Group 10 Sy 2,000.000 0285-711- Optional Base, Base Group 11 Sy 2,000.000 0285-712- Optional Base, Base Group 12 Sy 2,000.000 0285-715- Optional Base, Base Group 15 Sy 2,000.000 0327- 70- 1 Milling Exist Asph Pavt, 1" Avg Depth Sy 10,000.000 0327- 70- 4 Milling Exist Asph Pavt, 3" Avg Depth Sy 10,000.000 0327- 70- 5 Milling Exist Asph Pavt, 2" Avg Depth Sy 10,000.000 0327- 70- 6 Milling Exist Asph Pavt, 1 1/2" Avg Depth Sy 10,000.000 0327- 70- 8 Milling Exist Asph Pavt, 2 1/2" Avg Depth Sy 10,000.000 0327- 70- 19 Milling Exist Asph Pavt, 3/4" Avg Depth Sy 10,000.000 0334- 1- 11 Superpave Asphaltic Conc, Traffic a Tn 200.000 0334- 1- 12 Superpave Asphaltic Conc, Traffic b Tn 200.000 0334- 1- 13 Superpave Asphaltic Conc, Traffic c Tn 200.000 0337- 7- 25 Asphalt Concrete Friction Course, Inc Bit, Fc-5, Pg 76-22 Tn 200.000 0337- 7- 26 Asphalt Concrete Friction Course, Inc Bit, Fc-5, HighPolymerTn 200.000 0337- 7- 80 Asphalt Concrete Friction Course,Traffic b, Fc-9.5, Pg 76-22Tn 200.000 0337- 7- 81 Asphalt Concrete Friction Course,Traffic b, Fc-12.5, Pg 76-22Tn 200.000 0337- 7- 82 Asphalt Concrete Friction Course,Traffic c, Fc-9.5, Pg 76-22Tn 200.000 0337- 7- 83 Asphalt Concrete Friction Course,Traffic c, Fc-12.5, Pg 76-22Tn 200.000 0425- 1-321 Inlets, Curb, Type p-2, <10` Ea 2.000 0425- 1-471 Inlets, Curb, Type 7, <10` Ea 2.000 0425- 1-503 Inlets, Dt Bot, Type a, j Bot, <10` Ea 2.000 0425- 1-521 Inlets, Dt Bot, Type c,<10` Ea 2.000 0425- 1-541 Inlets, Dt Bot, Type d, <10` Ea 2.000 0425- 1-542 Inlets, Dt Bot, Type d, >10` Ea 2.000 0425- 3- 43 Junction Box, Drainage, p-7, Partial Ea 2.000 0425- 5- Manhole, Adjust Ea 2.000 0425- 6- Valve Boxes, Adjust Ea 2.000 0425- 13- 18 Drainage Structure Pipe Connection Screen 18" PipeDiameterEa 2.000 0430-174-118 Pipe Culvert, Optional Material, Round, 18"Sd Lf 50.000 0430-174-124 Pipe Culvert, Optional Material, Round, 24"Sd Lf 50.000 0430-175-118 Pipe Culvert,Optional Material,Round, 18"s/Cd Lf 50.000 0430-175-124 Pipe Culvert,Optional Material,Round, 24"s/Cd Lf 50.000 0430-175-218 Pipe Culvert,Optional Material,Other-Elip/Arch, 18"s/Cd Lf 50.000 0430-175-224 Pipe Culvert,Optional Material,Other Shape-Elip/Arch,24"s/CdLf 50.000 0430-982-125 Mitered End Section, Optional Round, 18" Cd Ea 2.000 0430-982-129 Mitered End Section, Optional Round, 24" Cd Ea 2.000 0430-984-125 Mitered End Section, Optional Round, 18" Sd Ea 2.000 0430-984-129 Mitered End Section, Optional Round, 24" Sd Ea 2.000 0515- 1- 1 Pipe Handrail - Guiderail, Steel Lf 100.000 0515- 1- 2 Pipe Handrail - Guiderail, Aluminum Lf 100.000 0515- 1- 41 Pipe Handrail - Guiderail, Relocate, Steel Lf 100.000 0515- 1- 42 Pipe Handrail - Guiderail, Relocate, Aluminum Lf 100.000 0520- 1- 7 Concrete Curb & Gutter, Type e Lf 1,000.000 0520- 1- 10 Concrete Curb & Gutter, Type f Lf 1,000.000 0520- 2- 2 Concrete Curb, Type b Lf 1,000.000 0520- 2- 4 Concrete Curb, Type d Lf 1,000.000 0520- 5- 11 Traffic Separator Concrete-Type i, 4` Wide Lf 500.000 0520- 5- 12 Traffic Separator Concrete-Type i, 6` Wide Lf 500.000 0520- 5- 16 Traffic Separator Concrete- Type i, 8.5` Wide Lf 500.000 0520- 5- 21 Traffic Separator - Concrete, Type Ii, 4` Wide Lf 500.000 0520- 5- 22 Traffic Separator - Concrete, Type Ii, 6` Wide Lf 500.000 0520- 5- 26 Traffic Separator Concrete- Type Ii, 8.5` Wide Lf 500.000 0520- 5- 41 Traffic Separator Concrete- Type Iv, 4` Wide Lf 500.000 0520- 5- 42 Traffic Separator Concrete- Type Iv, 6` Wide Lf 500.000 0520- 5- 46 Traffic Separator Concrete- Type Iv, 8.5` Wide Lf 500.000 0520- 70- Concrete Traffic Separator, Special- Variable Width Sy 500.000 0521- 72- 40 Shoulder Concrete Barrier, 38" Or 44" Height Lf 100.000 0521- 72- 43 Shoulder Concrete Barrier, Curb And Gutter Barrier Lf 100.000 0522- 1- Concrete Sidewalk And Driveways, 4" Thick Sy 600.000 0522- 2- Concrete Sidewalk And Driveways, 6" Thick Sy 600.000 0526- 1- 2 Pavers, Architectural, Sidewalk Sy 100.000 0527- 2- Detectable Warnings Sf 200.000 0570- 1- 2 Performance Turf, Sod Sy 4,000.000 Section 0002 Signing 0700- 1- 11 Single Post Sign, f&i Ground Mount, Up To 12 Sf As 15.000 0700- 1- 12 Single Post Sign, f&i Ground Mount, 12-20 Sf As 5.000 0700- 1- 13 Single Post Sign, f&i Ground Mount, 21-30 Sf As 5.000 0700- 1- 50 Single Post Sign, Relocate As 10.000 0700- 1- 60 Single Post Sign, Remove As 15.000 0700- 2- 11 Multi- Post Sign, f&i Ground Mount, Up To 12 Sf As 2.000 0700- 2- 12 Multi- Post Sign, f&i Ground Mount, 12-20 Sf As 2.000 0700- 2- 13 Multi- Post Sign, f&i Ground Mount, 21-30 Sf As 1.000 0700- 2- 50 Multi- Post Sign, Ground Mount, Relocate As 1.000 0700- 2- 60 Multi- Post Sign, Remove As 1.000 0700- 3-101 Sign Panel, Furnish & Install Ground Mount, Up To 12 Sf Ea 10.000 0700- 3-102 Sign Panel, Furnish & Install Ground Mount, 12-20 Sf Ea 2.000 0700- 3-103 Sign Panel, Furnish & Install Ground Mount, 21-30 Sf Ea 2.000 0700- 3-201 Sign Panel, Furnish & Install Overhead Mount, Up To 12 Sf Ea 10.000 0700- 3-202 Sign Panel, Furnish & Install Overhead Mount, 12-20 Sf Ea 2.000 0700- 3-203 Sign Panel, Furnish & Install Overhead Mount, 21-30 Sf Ea 1.000 0700- 3-501 Sign Panel, Relocate, Up To 12 Sf Ea 20.000 0700- 3-502 Sign Panel, Relocate, 12-20 Sf Ea 10.000 0700- 3-601 Sign Panel, Remove, Up To 12 Sf Ea 10.000 0700- 3-602 Sign Panel, Remove, 12-20 Sf Ea 5.000 0700- 5- 21 Internally Illuminated Sign, Furnish & Install OverheadMount, Up To 12 SfEa 1.000 0700- 5- 22 Internally Illuminated Sign, Furnish & Install, OverheadMount, 12-18 SfEa 1.000 0700- 11-112 Electronic Display Sign, Furnish & Install Ground MountacPowered, Electronic Warning Sign, 12-20 SfAs 2.000 0700- 11-122 Electronic Display Sign, Furnish & Install Ground MountacPowered, Electronic Regulatory Sign, 12-20 SfAs 2.000 0700- 11-132 Electronic Display Sign, Furnish & Install Ground MountacPowered, Speed Feedback Sign, 12-20 SfAs 2.000 0700- 11-142 Electronic Display Sign, Furnish & Install Ground MountacPowered, Elect Warning w/Flashing Beacon, 12-20 SfAs 2.000 0700- 11-152 Electronic Display Sign, Furnish & Install Ground MountacPowered, Elect Regulatory w/Flashing Beacon, 12-20SfAs 2.000 0700- 11-162 Electronic Display Sign, Furnish & Install Ground MountacPowered, Speed Feedback w/Flashing Beacon, 12-20 SfAs 2.000 0700- 11-222 Electronic Display Sign, Furnish & Install Ground MountsolarPowered, Electronic Regulatory Sign, 12-20 SfAs 2.000 0700- 11-231 Electronic Display Sign, Furnish & Install Ground MountsolarPower, Speed Feedback, Up To 12 SfAs 2.000 0700- 11-241 Electronic Display Sign, Furnish & Install Ground MountsolarPower, Elect Warning w/Flashing Beacon, Up To 12SfAs 2.000 0700- 11-251 Electronic Display Sign, Furnish & Install Ground MountsolarPowe, Elect Regulatory w/Flashing Beacon, Up To12 SfAs 2.000 0700- 11-261 Electronic Display Sign, Furnish & Install Ground MountsolarPowe, Speed Feedback w/Flashing Beacon, Up To 12SfAs 2.000 0700- 11-391 Electronic Display Sign, Furnish & Install OverheadMount- Ac Powered, Blank Out Sign, Up To 12 SfAs 2.000 0700- 11-500 Electronic Display Sign, Relocate As 2.000 0700- 11-600 Electronic Display Sign, Remove- Ground Mount As 2.000 0700- 11-700 Electronic Display Sign, Remove- Overhead Mount As 2.000 0700- 12- 11 Sign Beacon, f&i Ground Mount- Ac Powered, One Beacon As 2.000 0700- 12- 12 Sign Beacon, f&i Ground Mount- Ac Powered, Two Beacon As 2.000 0700- 12- 21 Sign Beacon, f&i Ground Mount- Solar Powered, OneBeaconAs 2.000 0700- 12- 22 Sign Beacon, f&i Ground Mount- Solar Powered, TwoBeaconsAs 2.000 0700- 13- 12 Retroreflective Sign Strip- Furnish And Install, 2` Ea 10.000 0700- 13- 15 Retroreflective Sign Strip- Furnish And Install, 5` Ea 10.000 0705- 11- 1 Delineator, Flexible Tubular Ea 30.000 0705- 11- 3 Delineator, Flexible High Visability Median Ea 10.000 0705- 11- 4 Delineator, Flexible High Performance 48" Ea 10.000 0706- 3- Retro-Reflective/Raised Pavement Markers Ea 270.000 0710- 11-101 Painted Pavement Markings, Standard, White, Solid, 6" Gm 1.000 0710- 11-102 Painted Pavement Markings, Standard, White, Solid ForInterchange And Urban Island, 8"Gm 1.000 0710- 11-123 Painted Pavement Markings, Standard, White, Solid ForCrosswalk And Roundabout, 12"Lf 500.000 0710- 11-124 Painted Pavement Markings, Standard, White, Solid ForDiagonal Or Chevron, 18"Lf 200.000 0710- 11-125 Painted Pavement Markings, Standard, White, Solid ForStop Line Or Crosswalk, 24"Lf 400.000 0710- 11-131 Painted Pavement Markings, Standard, White, Skip, 10-30Or 3-9 Skip, 6" WideGm 1.000 0710- 11-133 Painted Pavement Marking, Standard,White, 3`-9` Skip DropLine And Approach To Toll Plaza, 12" Wide,Gm 0.500 0710- 11-141 Painted Pavement Markings, Standard, White, 2-4 DottedGuideline/ 6-10 Dotted Extension, 6"Gm 0.500 0710- 11-160 Painted Pavement Markings, Standard, White, Message OrSymbolEa 20.000 0710- 11-170 Painted Pavement Markings, Standard, White, Arrows Ea 20.000 0710- 11-201 Painted Pavement Markings, Standard, Yellow, Solid, 6" Gm 1.000 0710- 11-202 Painted Pavement Markings, Standard, Yellow, Solid ForInterchange And Urban Island, 8"Gm 1.000 0710- 11-203 Painted Pavement Markings, Standard, Yellow, Solid, 12" Gm 1.000 0710- 11-224 Painted Pavement Markings, Standard, Yellow, Solid ForDiagonal Or Chevron, 18"Lf 100.000 0710- 11-231 Painted Pavement Markings, Standard, Yellow, Skip, 6" Gm 1.000 0710- 11-290 Painted Pavement Markings, Standard, Yellow, IslandNoseSf 100.000 0711- 11-102 Thermoplastic, Standard, White, Solid, 8" ForInterchange And Urban IslandGm 1.000 0711- 11-123 Thermoplastic, Standard, White, Solid, 12" For CrosswalkAnd RoundaboutLf 1,000.000 0711- 11-124 Thermoplastic, Standard, White, Solid, 18" For DiagonalsAnd ChevronsLf 400.000 0711- 11-125 Thermoplastic, Standard, White, Solid, 24" For Stop LineAnd CrosswalkLf 200.000 0711- 11-141 Thermoplastic, Standard, White, 2-4 Dotted Guideline/ 6-10Gap Extension, 6"Gm 1.000 0711- 11-160 Thermoplastic, Standard, White, Message Or Symbol Ea 20.000 0711- 11-170 Thermoplastic, Standard, White, Arrow Ea 25.000 0711- 11-224 Thermoplastic, Standard, Yellow, Solid, 18" For DiagonalOr ChevronLf 200.000 0711- 14-123 Thermoplastic, Preformed, White, Solid, 12" ForCrosswalkLf 250.000 0711- 14-125 Thermoplastic, Preformed, White, Solid, 24" ForCrosswalkLf 400.000 0711- 14-660 Thermoplastic, Preformed, Multi Color Route Shield Ea 5.000 0711- 15-101 Thermoplastic, Standard-Open Graded Asphalt SurfacesWhite, Solid, 6"Gm 1.000 0711- 15-102 Thermoplastic, Standard-Open Graded Asphalt Surfaces,White, Solid, 8"Gm 1.000 0711- 15-131 Thermoplastic, Standard-Open Graded Asphalt Surfaces,White, Skip, 6",10-30 Skip Or 3-9 Lane DropGm 1.000 0711- 15-201 Thermoplastic, Standard-Open Graded Asphalt Surfaces,Yellow, Solid, 6"Gm 1.000 0711- 15-202 Thermoplastic, Standard-Open Graded Asphalt SurfacesYellow, Solid, 8"Gm 1.000 0711- 15-231 Thermoplastic, Standard-Open Graded Asphalt Surfaces,Yellow, Skip, 6"Gm 1.000 0711- 16-131 Thermoplastic, Other Surfaces, White, Skip, 6",10-30 Skip Or3-9 Lane DropGm 0.500 0711- 16-133 Thermoplastic, Standard-Other Surfaces White, Skip, 12"-Approach To Toll Plaza Or 3-9 Lane DropGm 0.500 0711- 16-202 Thermoplastic, Standard-Other Surfaces, Yellow, Solid,8"Gm 1.000 0711- 17- Thermoplastic, Remove Existing Thermoplastic PavementMarkings: Non-Conflicting OnlySf 1,000.000 Section 0003 Signalization 0630- 2- 11 Conduit, Furnish & Install, Open Trench Lf 100.000 0630- 2- 12 Conduit, Furnish & Install, Directional Bore Lf 100.000 0630- 2- 14 Conduit, Furnish & Install, Aboveground Lf 100.000 0632- 7- 2 Signal Cable- Repair/Replace/Other, Furnish & Install Lf 1,000.000 0632- 7- 6 Signal Cable, Remove- Intersection Pi 2.000 0635- 2- 11 Pull & Splice Box, f&i, 13" x 24" Cover Size Ea 4.000 0635- 2- 12 Pull & Splice Box, f&i, 24" x 36" Cover Size Ea 4.000 0635- 2- 13 Pull & Splice Box, f&i, 30" x 60" Rectangular Or 36" RoundCover SizeEa 4.000 0635- 3- 11 Junction Box, Furnish & Install, Aerial Ea 4.000 0639- 1-112 Electrical Power Service, f&i, Overhead MeterPurchased By Contractor From Power CompanyAs 4.000 0639- 1-122 Electrical Power Service, f&i, Underground, MeterPurchased By ContractorAs 4.000 0639- 2- 1 Electrical Service Wire, Furnish & Install Lf 500.000 0646- 1- 11 Aluminum Signals Pole, Pedestal Ea 5.000 0646- 1- 60 Aluminum Signals Pole, Remove Ea 4.000 0650- 1- 11 Vehicular Traffic Signal, Furnish & Install Aluminum, 1Section, 1 WayAs 5.000 0650- 1- 12 Vehicular Traffic Signal, Furnish & Install Aluminum, 1Section, 2-4 WayAs 5.000 0650- 1- 14 Vehicular Traffic Signal, Furnish & Install Aluminum, 3Section, 1 WayAs 5.000 0650- 1- 15 Vehicular Traffic Signal, Furnish & Install Aluminum, 3Section, 2-4 WaysAs 5.000 0650- 1- 16 Vehicular Traffic Signal, Furnish & Install Aluminum, 4Section, 1 WayAs 5.000 0650- 1- 17 Vehicular Traffic Signal, Furnish & Install Aluminum, 4Section, 2-4 WaysAs 5.000 0650- 1- 19 Vehicular Traffic Signal, Furnish & Install Aluminum, 5Section Cluster, 1 WayAs 5.000 0650- 1- 24 Vehicular Traffic Signal, Furnish & Install Polycarbonatew/Alum Top, 3 Section, 1 WayAs 5.000 0650- 1- 25 Vehicular Traffic Signal, Furnish & InstalPolycarbonate With Aluminum Top Section, 3 Section, 2-4 wAs 5.000 0650- 1- 26 Vehicular Traffic Signal, Furnish & Install Polycarbonatew/Alum Top, 4 Section, 1 WayAs 5.000 0650- 1- 29 Vehicular Traffic Signal, Furnish & Install Polycarbonatew Alumin, 5 Section Cluster, 1 WayAs 5.000 0650- 1- 34 Vehicular Traffic Signal, Furnish & InstallPolycarbonate, 3 Section, 1 WayAs 5.000 0650- 1- 35 Vehicular Traffic Signal, Furnish & InstallPolycarbonate, 3 Section, 2-4 WaysAs 5.000 0650- 1- 36 Vehicular Traffic Signal, Furnish & InstallPolycarbonate, 4 Section, 1 WayAs 5.000 0650- 1- 39 Vehicular Traffic Signal, Furnish & InstallPolycarbonate, 5 Section Cluster, 1 WayAs 5.000 0650- 1- 50 Vehicular Traffic Signal, Install As 5.000 0650- 1- 60 Vehicular Traffic Signal, Remove- Poles To Remain As 5.000 0650- 1- 70 Vehicular Traffic Signal, Relocate- Includes Removal AndReinstallationAs 5.000 0653- 1- 11 Pedestrian Signal, Furnish & Install Led Countdown, 1WayAs 5.000 0653- 1- 12 Pedestrian Signal, Furnish & Install Led Countdown, 2WaysAs 5.000 0653- 1- 60 Pedestrian Signal, Remove Ped Signal- Pole/Pedestal ToRemainAs 5.000 0654- 1- 10 In Roadway Light Assembly, Furnish & Install- Ac Powered,Complete CrossingAs 1.000 0654- 1- 20 In Roadway Light Assembly, Furnish & Install- SolarPowered, Complete CrossingAs 1.000 0654- 2- 11 Rectangular Rapid Flashing Beacon, Furnish & Install- AcPowered, Complete Sign Assembly- Single DirectionAs 10.000 0654- 2- 12 Rectangular Rapid Flashing Beacon, Furnish & Install- AcPowered, Complete Sign Assembly- Back To BackAs 10.000 0654- 2- 21 Rectangular Rapid Flashing Beacon, Furnish & InstallsolarPowered, Complete Sign Assembly- Single DirectionAs 10.000 0654- 2- 22 Rectangular Rapid Flashing Beacon, Furnish & InstallsolarPowered, Complete Sign Assembly- Back To BackAs 10.000 0654- 2- 30 Rectangular Rapid Flashing Beacon, Install CompleteSign AssemblyAs 10.000 0654- 2- 40 Rectangular Rapid Flashing Beacon, Relocate CompleteSign AssemblyAs 10.000 0654- 2- 50 Rectangular Rapid Flashing Beacon, Adjust/Modify As 10.000 0654- 2- 60 Rectangular Rapid Flashing Beacon, Remove CompleteSign AssemblyAs 10.000 0654- 3- 10 Pedestrian Hybrid Beacon Assembly, Furnish & InstallComplete AssemblyAs 2.000 0654- 3- 60 Pedestrian Hybrid Beacon Assembly, Remove As 2.000 0660- 1-109 Loop Detector Inductive, f&i, Type 9 Ea 5.000 0660- 1-110 Loop Detector Inductive, f&i, Type 10 Ea 5.000 0660- 2-102 Loop Assembly, f&i, Type b As 6.000 0660- 2-106 Loop Assembly, f&i, Type f As 9.000 0665- 1- 11 Pedestrian Detector, Furnish & Install, Standard Ea 16.000 0665- 1- 12 Pedestrian Detector, Furnish & Install, Accessible Ea 32.000 0665- 1- 60 Pedestrian Detector, Remove- Pole/Pedestal To Remain Ea 8.000 0670- 4- 1 Intersection Control Beacon Controller Assembly,Furnish & InstallAs 2.000 0670- 5-300 Traffic Controller Assembly, Install As 1.000 0670- 5-400 Traffic Controller Assembly, Modify As 1.000 | ||
Details |
|
||
Bidder's List | View project details and contacts | ||
Prospective Bidders | View project details and contacts | ||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |