Similar Projects
Roofing Repair and Maintenance
Post-Bid

CAA Roof Renovation
Post-Bid
Daphne, AL 36526

AFICC Enterprise Wide Roofing Repair, Replacement, and Maintenance (R3M)
Results

MATOC - Army Reserve National Roofing Program (NRP)
Results
Less than $95,000,000 est. value

Fire Station 2 Roof Replacement
Results
Less than $98,000 est. value
Gulf Shores, AL 36542

Replace Roofs on Anderson Boulevard Apartments
Results
Bay Minette, AL 36507

Hurricane Sally Roofing Repairs
Results
Orange Beach, AL 36561

Cultural Center Hurricane Sally Roof and Structure Repairs
Results
Less than $480,000 est. value
Gulf Shores, AL 36542

Former USA Building Roof Replacement
Results
Less than $27,650 est. value
Fairhope, AL 36532

The Haven Roof Replacement
Results
Less than $12,600 est. value
Fairhope, AL 36532

Tennis Center Roof Repair
Results
Less than $16,450 est. value
Fairhope, AL 36532

Recreation Center Roof Repairs - Volanta
Results
Fairhope, AL 36532

Foley Civic Center Roof & Sheet Metal Restoration Labor & Incidental Material Contract
Results
Foley, AL 36535

Fire Hall Roof Repairs
Results
Fairhope, AL 36532

Founders Park Roof Repair
Results
$38,700 est. value
Fairhope, AL 36532

Reported 08/24/2021 05:50 PM
Project Title

Covered Slip Roof and Framing Repairs at the Docks ( FEMA 4563)

Physical Address View project details and contacts
City, State (County) Fairhope, AL 36532   (Baldwin County)
Category(s) Single Trades
Sub-Category(s) Roofing
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value $32,965
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

To repair and replace portions of galvalume roof and wood structure/sheathing on the Covered Slips Pavilion at Fairhope Docks located at 848 Sea Cliff Drive, Fairhope, Alabama. Work shall include, provide all labor, equipment, materials and incidentals to complete the following work, including but not limited to: 1. Replace missing galvalume roofing panels lost to wind impacts from HC Sally - Minimum 425 SQ. FT. 2. Refasten and/or replace all roof panel fasteners within the entire field - ± 9,600 SQ. FT. 3. Repair and/or replace all damaged top plates, rafters, purlins, bracing and all other wood superstructure. 4. Add additional X-Bracing as shown on plan 5. Replace all fascia skirting (T1-11 Siding) at upper end of covered slips

Details

Division 07 - Thermal and Moisture Protection, Dampproofing and Waterproofing, Thermal Protection.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents