Similar Projects
Medical Office/Outpatient Construction Project Lead, Dallas, Grand Prairie, TX 75051 (Dallas County)
Last Updated | 06/12/2020 09:44 AM |
Project Title | Y1DA--Expand Dallas Specialty Primary Care Clinic 549-152 / Grand Prairie, TX |
Physical Address | View project details and contacts |
City, State (County) | Dallas, Grand Prairie, TX 75051 (Dallas County) |
Category(s) | Medical |
Sub-Category(s) | Medical Office/Outpatient |
Contracting Method | Competitive Bids. |
Project Status | Pre-Solicitation |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | Federal Agency |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | Y1DA--Expand Dallas Specialty Primary Care Clinic 549-152 / Grand Prairie, TX: Contractor to provide design and construction of the legal removal of hazardous materials as identified in the evaluation report, geotechnical report, verify that the current property survey is accurate, job trailer(s) with power, setting up and securing the staging area and the subcontractor parking area, and all design related elements / phasing as put forth by his A/E design team. New work will include but not be limited to the following: a new structural system that ties back into the existing system - The new system will include a new concrete foundation, new structural steel / concrete columns, new precast concrete parapets (to match the existing), new membrane roof system including roof drains, overflow drains, lighting protection, stainless steel flashing and filling in the existing courtyard opening in the roof. All interior wayfinding signage shall be provided and installed by the General contractor. A new interior roof ladder / hatch is to be provided in the area of the enclosed loading dock. In addition, new mechanical / electrical / plumbing / fire sprinkler and life safety systems and Information Technology systems will be required. New security fencing, bollards, blast resistant glass / tempered glass etc. will be required to meet the minimum requirements for Force Protection as established by the Veterans Affairs (VA). |
||||||||||||||||||||||||||||||||||||||||
Details |
|
||||||||||||||||||||||||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||||||||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||||||||||||||||||||||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |