Similar Projects
Verano and Conchas Loops Waterline and Service Lateral Replacements
Infrastructure
Bidding
$300,000 est. value
Santa Fe, NM

Water System SCADA Study
Infrastructure
Bidding
Los Alamos, NM

El Creston MDWCA Water System Improvements Project
Post-Bid
Las Vegas, NM 87701

The Heredia Community Ditch Association
New Construction
Post-Bid
San Lorenzo, NM

Valle Del Rio Water System Improvements
Results
La Mesa, NM

4610--VHA Mar Cor Reverse Osmosis Water Purification BNOE | Sources Sought | 36U10120Q0029
Results

Spaceport Water Services
Infrastructure
Bidding
Santa Fe, NM

Water System Improvements
Post-Bid
$540,000 to $610,000 est. value
Tatum, NM

Pena Blanca Water and Sanitation District Water System Improvements
Results
Pena Blanca, NM 87041

Lower Arroyo Hondo MDWCA Water System Improvements Project
Infrastructure
Bidding
$500,000 est. value
Arroyo Hondo, NM

Riverside Waterline and Spring Tank Replacement
Post-Bid
Ruidoso Downs, NM

Construction of the Union Del Llano Phase II Water System Improvements
Results
Llano, NM 87543

Amorak Road Water Improvements Project
Infrastructure
Bidding
$598,000 est. value
Ranchos de Taos, NM 87557

Lea County Airport Water and Sewer Extension
Post-Bid
Hobbs, NM 88240

Mountain View Waterline Extension
Results
$500,000 to $700,000 est. value
Moriarty, NM 87035

Last Updated 04/27/2022 12:06 PM
Project Title

NM6 Waterline Extension Project 1B Phase 1

Physical Address View project details and contacts
City, State (County) Los Lunas, NM   (Valencia County)
Category(s) Sewer and Water
Sub-Category(s) Water Lines
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value $2,500,000
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Work Includes all elements of construction for the complete of construction and fully functional facilities defined on this project: 1. Construct 12-inch diameter waterline, approximately 960 feet, 18-inch diameter waterline approximately 7,230 feet, and all related appurtenances. 2. Construct jack and bore crossing for 18-inch waterline. 3. Construct approximately 8,270 feet of fiber optic conduit and 11 pullboxes.

Details

Division 33 - Utilities, Instrumentation and Control for Utilities, Water Utilities, Water Utility Distribution Piping, Water Utility Distribution Equipment, Disinfecting of Water Utility Distribution, Water Utility Storage Tanks.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents