Similar Projects
Jenkins Terrace / Worley Terrace - Lighting Upgrades
Bidding
$300,000 est. value
Columbus, OH

Big Run Maintenance Conversion
Post-Bid
Less than $250,000 est. value
Columbus, OH 43205

JPWWTP- Electric Gate Actuators
Post-Bid
Columbus, OH

69 KV Underground Cable Replacement
Results
Less than $1,600,000 est. value
Westerville, OH 43081

2019 DCS Electrical Improvements
Results
Dublin, OH

Generator Inspection and Maintenance Services
Term Contract
Post-Bid
Westerville, OH

Design-Build Services
Results
Columbus, OH 43211

Division of Power Curtailment Service Provider
Post-Bid
Columbus, OH

EV Charging Stations for the Northern Lights Park and Ride and the Northland Transit Center
Results
Less than $140,095 est. value
Columbus, OH 43085

2019 Electric Vehicle Charging Stations
Post-Bid
Upper Arlington, OH

PS/Traffic/ 7 Cond Traffic Wire
Results
Columbus, OH

S and DJP - UPS
Post-Bid
Columbus, OH

North Central Standard Lighting
Results
Columbus, OH 43215

Construction Manager at Risk and Design-Assist Services for Energy Savings Projects
Post-Bid
Columbus, OH

DOP - 2019 - Potential Transformers for Stock
Results
Columbus, OH

Last Updated 02/27/2020 04:13 PM
Project Title

14060 Reliability Improvements

Physical Address View project details and contacts
City, State (County) Columbus, OH   (Franklin County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

Circuit 14060 Reliability Improvements (CIP 670893-100000), the work for which consists of replacing nearly 100 wood distribution poles, 500 crossarms, 300 potted porcelain fused cutouts, 250 gapped lighting arresters, and 17,000 circuit feet of conductor. In addition, three new electronic reclosers, three gang-operated air breaks, and 21 solid blade disconnects will be installed to improve operational flexibility. To minimize the number of customers interrupted by future unplanned outages, over 300 fused cutouts will have their fuse link changed to make sure the system protection is properly coordinated. System neutrals will also be added to improve safety and system protection.

Details

Division 26 - Electrical.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents