Similar Projects
Replace HVAC Units Building 7050
Design
$500,000 to $1,000,000 est. value
Fort Hood, TX

Kitchen Hood Service
Post-Bid
Fort Hood, TX

J--Furnish and Install New Metasys Bas Tec Programmable Controllers 674-20-1-5065-0110
Post-Bid
Temple, TX 76504

Replace Two Chiller Circuites for a Building
Results
$250,000 to $500,000 est. value
Killeen, TX 76544

Replace HVAC at Building
Results
$500,000 to $1,000,000 est. value
Fort Hood, TX 76544

41--JMITS Test Van Air Conditioner Replacement Units
Post-Bid
Fort Hood, TX

41--CTX Mobile Chiller Unit
Results
Temple, TX 76504

4510--Cooling Tower Water Treatment Stations
Post-Bid
Temple, TX 76504

Replace Chillers Building 56059
Results
$100,000 to $250,000 est. value
Fort Hood, TX 76544

HVAC Services, Supplies and Equipment
Post-Bid
$50,000 to $150,000 est. value
Belton, TX 76513

J041--New-Temple AHU 7 CHW Pump & Bypass (VA-19-00102647)
Results
Temple, TX 76504

Installation of Bathroom Ventilation Fans at Belton Housing Authority
Post-Bid
Belton, TX 76513

Replace HVAC Systems Building 70020
Results
$500,000 to $1,000,000 est. value
Fort Hood, TX 76544

Suppliers of Daikin/Mcquay HVAC Chiller Units
Post-Bid
Fort Hood, TX

Replace Chillers in Building 56055
Results
$100,000 to $250,000 est. value
Fort Hood, TX 76544

Reported 09/17/2020 12:00 AM
Project Title

6515--Nucmed Fume Hood

Physical Address View project details and contacts
City, State (County) Temple, TX   (Bell County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Request for Quotations
Bids Due View project details and contacts
Estimated Value
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

The Nuclear Medicine Service needs a fume hood to replace old unit that is beyond repair. The fume hood needs to be specifically made to shield radioactivity used in nuclear medicine. The shielding should be built into the back, sides and bottom but also incorporate lead glass in the front. Fume Hood acceptable qualities: Class II, Type A2 Recirculating Exhaust Hood Integrated Supply and Exhaust HEPA Filtration (99.99+% @ 0.3 um) contains hazards while providing laminar ISO 5 air within the BSC Lead shielding (1/4", 1/2", 1" or 2") on sides, bottom and back Dose Calibrator Chamber flushed to countertop Lead shielding for dose calibrator chamber (1/4", 1/2", 1" or 2") Lead shielding for sharps container (1/4", 1/2", or 1") Must be 3 foot wide and include a base Item # Description/Part Number* Qty 0001 Labconco Logic + 3 Hood LABCONCO LOGIC + 3 HOOD CLASS II A2 HOOD 1/4 LEAD SHEILDING SIDE BACK & BOTTOM 1 3. Background: This is replacement equipment for the Imaging Service. This fume hood will allow the facility to continue to use radiopharmaceuticals for direct patient care. Current fume hood is beyond repair.

Details

Division 11 - Equipment, Laboratory Equipment, Laboratory Fume Hoods.
Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents