Similar Projects
Last Updated | 10/06/2021 08:58 AM |
Project Title | USDA-ARS Beltsville Agricultural Research Center (BARC) Building 308 Renovation |
Physical Address | View project details and contacts |
City, State (County) | Beltsville, MD 20705 (Prince Georges County) |
Category(s) | Animal/Plant/Fish Facility |
Sub-Category(s) | Animal/Plant/Fish Facility |
Contracting Method | Design-Build. Competitive Bids. |
Project Status | Pre-Solicitation |
Bids Due | View project details and contacts |
Estimated Value | $25,000,000 to $100,000,000 |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | Construction services for the USDA-ARS Beltsville Agricultural Research Center (BARC) Building 308 Renovation: proposed project will be a competitive, firm-fixed-price (FFP), design-build (DB) contract: Scope includes the gut interior and replace demolished features for desired function. Load bearing columns and exterior walls to remain. Interior walls can be demolished or moved as required per floorplan design. Replace/upgrade all utilities (telecom, data, mechanical, electrical, plumbing, fire protection, etc.). All buildings shall receive 480-volt electrical service and transformers as necessary. All utilities shall be replaced from building exterior back to main service connection. Building envelope and drainage features to ensure all exterior walls are “weathertight” and “watertight”. Exterior building drainage systems and roofs shall be replaced as part of building renovation. DB contractor shall perform all landscaping work. BARC will remove any furniture and equipment that they want to salvage; Remaining existing furniture, equipment and trash will be removed by the DB Contractor. Mitigate hazardous materials (asbestos, mold, etc.) as necessary, utilizing hazmat surveys completed by USACE Baltimore. Replace laboratory equipment, fume hoods, and casework. At Building 308, steam line will be replaced from building to exterior junction manhole for adjacent buildings. Service shutdown shall be coordinated. Elevators at each building shall be installed per floorplan design and meet building code requirements. Exterior work to be covered includes roof replacement or repair, removal of fire escapes, window replacements, replacement of exterior building features, building lighting, sidewalks, ramps, and parking spaces needed for ADA compliance. Interior staircases shall be installed per design, to meet code. The attics shall be completely weather tight and environmental contaminants shall be mitigated as necessary. New work shall be completed in a manner to preserve historical appearance and significance of existing structures. |
||||||||||||||||||||||||||||||||||||||
Details |
|
||||||||||||||||||||||||||||||||||||||
Bidder's List | View project details and contacts | ||||||||||||||||||||||||||||||||||||||
Prospective Bidders | View project details and contacts | ||||||||||||||||||||||||||||||||||||||
Project Documents |
![]() Engineered Spec Sheet ![]() Architectural Plans ![]() Other Documents |