Similar Projects
Indefinite Delivery/Indefinite Quantity Electronic Security Systems (ESS) 7th Generation
Term Contract
Design
Less than $675,000,000 est. value

Standby Generator Replacement, Franklin Falls Dam, Franklin, NH
Term Contract
Bidding
$25,000 to $100,000 est. value
Franklin, NH

Energy Performance Contracting Services
Post-Bid
Concord, NH 03301

Cleveland/Rudman Lighting Control Systems Replacement
Post-Bid
$250,000 to $500,000 est. value
Concord, NH

Community Solar Photovoltaic (PV)
Results

UPS Maintenance
Term Contract
Results
Concord, NH

Fy21 R1 New England Electric Supply
Term Contract
Post-Bid

Electrical Systems Services and Repairs
Results
Concord, NH

Two (2) Generators Supply and Install
Alteration
Post-Bid
$20,000 est. value
Concord, NH

Solar Photovoltaic Power Generating System
Alteration
Results
Boscawen, NH

Keasarge Middle School Lighting Upgrades
Alteration
Results
North Sutton, Sutton, NH 03260

Generator Supply and Install
Alteration
Results
Loudon, NH

Energy Recovery System
Alteration
Results
Bow, NH 03304

Emergency Backup Generator Installation
Alteration
Results
Bow, NH 03304

ECTC Electrical Generator Replacement
Alteration
Results
$824,000 est. value
NH

Reported 04/28/2022 12:00 AM
Project Title

Gatehouse Emergency Lighting Installation, Franklin Falls Dam, Franklin

Physical Address View project details and contacts
City, State (County) Franklin, NH   (Merrimack County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Request for Quotations, Construction Start Expected May 2022
Bids Due View project details and contacts
Estimated Value $25,000 [brand] Estimate
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Furnish all labor, materials, and equipment necessary to install a total of ten (10) light emitting diode (LED) emergency lighting units with battery backup in the main entry level and subfloor, one (1) illuminated exit sign, and replace one (1) existing high intensity discharge (HID) exterior wall pack with a LED wall pack. Emergency battery units shall be wired to the nearest lighting circuit ahead of any switch leg. Emergency battery units are to be installed for the purpose of safety and shall automatically come on when utility power is cut, turn off when power is returned either by generator or the utility power, and be adequately charging when in standby mode. The one LED wall pack shall be wired and equipped with a photocell sensor. Project location is Franklin Falls Dam Gatehouse, Franklin, NH.

Details

Division 26 - Electrical.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents