Similar Projects
WWRF Door Replacement Project
Bidding
Miramar, FL 33027

Repair of Electric Gates
Post-Bid
Sunrise, FL 33351

Impact Windows
Post-Bid
Parkland, FL 33067

Public Safety Building Ballistic Glass Replacement Project
Results
Sunrise, FL 33351

Furnish and Install Automatic Swing Operators on Existing Doors in Sunrise Civic Center
Results
Sunrise, FL 33351

Impact Windows
Post-Bid
Hollywood, FL 33024

Central Park Multi-Purpose Center Exterior Door/Window and Roof Replacement
Results
Less than $194,000 est. value
Plantation, FL 33324

Automatic Door Repair and Maintenance
Term Contract
Post-Bid
$230,000 est. value
Fort Lauderdale, FL 33315

Fire Station Hurricane Wind Retrofit for Bay Garage Doors
Results
Davie, FL 33314

Impact Windows and Doors
Renovation
Post-Bid
Plantation, FL 33322

Fire Station Hurricane Wind Retrofit for Windows and Doors
Term Contract
Results
$84,600 to $289,213 est. value
Davie, FL 33325

Hugh Taylor Birch State Park - Terramar Improvements
Results
Fort Lauderdale, FL 33304

Cultural Arts Banquet Hall Door Replacement
Results
Miramar, FL 33025

Fire Stations 34 and 44 Wind Retrofit-HMGP
Results
Less than $987,010 est. value
North Lauderdale, FL 33068

Replacement of Windows and Doors for the Hazard Mitigation Grant
Results
Less than $386,000 est. value
Pembroke Pines, FL 33027

Last Updated 05/28/2020 04:59 AM
Project Title

Central Park Multi-Purpose Building Windows, Storefronts, and Doors Removal and Replacement

Physical Address View project details and contacts
City, State (County) Fort Lauderdale, Plantation, FL 33324   (Broward County)
Category(s) Single Trades
Sub-Category(s) Windows/Doors
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

The scope of work shall include the removal of existing exterior aluminum window assemblies, exterior Steel & Aluminum door assemblies and replacement with new impact rated assemblies meeting current Florida Building Code and Miami Dade County NOA requirements. Impact ratings shall include complete systems including but not limited to, all mullions and associated hardware. The windows, storefront and door system assemblies shall be designed to withstand minimum design pressures and impacts in compliance with the current edition of the Florida Building Code and the Miami-Dade Department of Regulatory and Economic Resources - Board and Code Administration Division, Notice of Acceptance (NOA). Glazing (Base bid) shall be clear with no insulation or Low-E coating. Glazing (Alternate bid) shall include Solarban 70 Solar Control Low-E Glass, or approved equal. Aluminum Window frames shall receive a Black anodized finish. Windows assemblies shall be Winguard 700 Series Aluminum Fixed Pane as manufactured by PGT Industries, or approved equal. Storefront Systems Shall be PGT/CGIC and metal doors shall be Steel doors from Steelcraft.

Details

Division 08 - Openings, Doors and Frames, Metal Doors and Frames, Aluminum Doors and Frames, Stainless-Steel Doors and Frames, Metal Doors, Aluminum Doors, Stainless-Steel Doors, Windows, Metal Windows, Aluminum Windows, Stainless-Steel Windows, Steel Windows.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents