Similar Projects
Utility Monitoring and Control Systems
Post-Bid
Less than $2,100,000,000 est. value

Utility Monitoring and Control Systems
Post-Bid
Less than $2,100,000,000 est. value

Water Intrusion
Results
Columbia, SC

Grier Student Center Chiller Replacement
Results
$367,429 est. value
Greenwood, SC

Replace HVAC Systems and Water Heaters at Florence School District 5, Johnsonville Middle School
Post-Bid
$500,000 to $1,000,000 est. value
Johnsonville, SC

HVAC Renovation for Bldg 174 Aerial Delivery Facility
Results
$250,000 to $500,000 est. value
Charleston, SC 29404

Sumter Street HVAC Replacement
Post-Bid
$500,000 to $550,000 est. value
Columbia, SC

Senior Center HVAC System
Results
Central, SC

HVAC Maintenance Service and Repairs for 2019
Term Contract
Post-Bid
Pineridge, SC

Geology Building - Repair - Replace Roof Top HVAC Unit
Results
$139,000 est. value
Columbia, SC

Storm Eye Institute Chiller Replacement - Phase II
Post-Bid
$2,000,000 to $3,000,000 est. value
Charleston, SC

Back-up HVAC System for Server Room
Results
Charleston, SC 29415

Furnish/Install Cabinets Waccamaw MHC
Post-Bid
Conway, SC 29526

Robertson Hall Chiller
Results
$79,810 est. value
Spartanburg, SC

New Granite Counters for Ravenel Community Hall
Post-Bid
Ravenel, SC 29470

Reported 01/17/2019 12:00 AM
Project Title

Piedmont Crawl Space Encapsulation

Physical Address View project details and contacts
City, State (County) Newberry, SC 29108   (Newberry County)
Category(s) Single Trades
Sub-Category(s) Finishes/Interior, HVAC
Contracting Method Competitive Bids.
Project Status Request for Quotations
Bids Due View project details and contacts
Estimated Value
Plans Available from State Agency
Owner View project details and contacts
Architect View project details and contacts
Description Cover entire ground area and a minimum of 12" high on exterior walls and piers with a high density reinforced liner cover to limit for moisture control purposes. (Min. 8 MIL) Contractor to rake and smooth soil before installation. Seal all foundation vents from interior of crawl space. Install an Energy Star rated commercial crawl space humidifier with condensation pump. Must be rated for a minimum of 3,700 square feet. Unit must come with "automatic restart". Must be wired by a licensed electrician. Must provide gravity flow condensation line to extend to the exterior of building. Install a remote humidity sensor for owner to monitor crawl space humidity. Contractor to return in 30 days to adjust dehumidifier settings as needed and ensure proper condensation drainage.
Details
Division 02 - Existing Conditions, Subsurface Investigation.
Division 07 - Thermal and Moisture Protection.
Division 09 - Finishes.
Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.
Division 31 - Earthwork, Grading, Earthwork Methods.
Division 32 - Exterior Improvements, Retaining Walls.
Division 33 - Utilities.
Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents