Similar Projects
Last Updated | 04/09/2021 04:36 PM |
Project Title | Proposed Water Line Replacement - Contract 1 |
Physical Address | View project details and contacts |
City, State (County) | Paden City, WV 26157 (Wetzel County) |
Category(s) | Sewer and Water |
Sub-Category(s) | Water Lines |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | 1 LS Mobilization/Demobilization, 1 LS Sediment & Erosion Control Measures, 50 EA Test Pits, 6670 LF 8" CL-150 Water Pipe, 9450 LF 6" CL-150 Water Pipe, 36 LF 6" Ductile Iron CL-50 P.JT. Water Pipe, 70 LF 4" CL-150 Water Pipe, 205 LF 2" CL-150 Water Pipe, 21 EA 8" M.JT. Gate Valve, Complete With Box And Lid, 1 EA 8" M.JT. Gate Valve, Complete With Box And Lid, Installed On Existing 8" PVC Water Line, 19 EA 6" M.JT. Gate Valve, Complete With Box And Lid, 4 EA 6" M.JT. Gate Valve, Complete With Box And Lid, Installed On Existing 6" AC Water Line, 2 EA 4" M.JT. Gate Valve, Complete With Box And Lid, 16 EA Fire Hydrant Assembly, Complete In Place, 15 EA Remove And Replace Existing Fire Hydrant, Complete, 16 EA Remove Existing Fire Hydrant, 1 EA 2" Hidden Flushing Hydrant Assembly, Complete, 285 EA Existing Customer's Service Reconnection, Complete, 6,450 LF 3/4" Polyethylene SDR-9 Service Tubing (Open Cut), 6,500 LF 3/4" Polyethylene SDR-9 Service Tubing (Bore and Jack), 80 LF " Polyethylene SDR-9 Service Tubing (Open Cut), 45 LF 16" Steel Casing (Bore And Jack), Including Casing Spacers, 34 EA Abandon Existing Gate Valve, Complete In Place, 1 EA 8" Tie-In on Ex. 8" PVC, Complete, 2 EA 8" Tie-In on Ex. 6" CI, Complete, 1 EA 8" Tie-In on Ex. 8" AC, Complete, 3 EA 8" Tie-In on Ex. 4" AC, Complete, 2 EA 8" Tie-In on Ex. 6" PVC, Complete, 1 EA 8" Tie-In on Ex. 8" CI, 1 EA 8" Tie-In on Ex. 6" AC, 1 EA 8" Tie-In on Ex. 4" CI, 1 EA 8" Tie-In on Ex. 2" PVC, 1 EA 8" Tie-In on Ex. 4" PVC, 6 EA 6" Tie-In on Ex. 8" PVC, 5 EA 6" Tie-In on Ex. 4" AC, 2 EA 6" Tie-In on Ex. 6" CI, 1 EA 6" Tie-In on Ex. 6" AC, 1 EA 6" Tie-In on Ex. 8" CI, 1 EA 6" Tie-In on Ex. 4" PVC, 1 EA 6" Tie-In on Ex. 4" CI, 2 EA Ex. 3" C.I, Tie-In to New 8" PVC, 1 EA 2" Tie-In on Ex. 8" PVC, 1 EA 2" Tie-In on Ex. 6" AC, 1 EA Cut And Plug Ex. 8" AC Water Line, 1 EA Cut And Plug Ex. 6" PVC Water Line, 8 EA Cut And Plug Ex. 6" AC Water Line, 3 EA Cut And Plug Ex. 6" CI Water Line, 2 EA Cut And Plug Ex. 4" PVC Water Line, 11 EA Cut And Plug Ex. 4" AC Water Line, 5 EA Cut And Plug Ex. 4" CI Water Line, 1 EA Cut And Plug Ex. 2" HDPE Water Line, 1 EA Cut And Plug Ex. 2" PVC Water Line, 130 LF WVDOH Shoulder Stone Repair, 1 YD WVDOH ADA Concrete Sidewalk Repair, 85 YD Concrete City Street Repair, 40 YD Concrete Driveway/Road Repair, 8 YD Concrete Sidewalk Repair, 3 YD Concrete Curb Replacement, 1 YD Concrete Apron Replacement, 10240 LF HMA City Street Repair, 55 LF HMA Driveway/Road Repair, 30 LF HMA Apron Repair, 30 LF HMA Curb Replacement, 2,930 TN 2" HMA Overlay, W/ Roto Milling And Paint Markings, 3500 LF Gravel Driveway/Road Repair, 9500 LF Reclamation Of Disturbed Areas. |
||
Details |
|
||
Bidder's List | View project details and contacts | ||
Prospective Bidders | View project details and contacts | ||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |