Similar Projects
HVAC Air Filters
Term Contract
Bidding
Syracuse, NY

Geneva Tower VRV HVAC Upgrades
Renovation
Post-Bid
Syracuse, NY 13205

HVAC/Refrigeration Replacement & Maintenance
Term Contract
Post-Bid

Centravac Chiller - Adaptive Frequency Drive Upgrade
Results
Syracuse, NY 13210

Main Boiler Plant Combustion Ventilation and Reverse Osmosis System
Results
Syracuse, NY 13210

2021 HVAC Mechanical Maintenance and Emergency Repair Contract
Post-Bid
East Syracuse, NY 13057

Furnish Steam Coil Replacement
Term Contract
Results
Syracuse, NY 13202

Z1DA--528A7-18-720 COVID-19: REPLACE AHU 04, 06, 22, 34, 36
Post-Bid
$2,000,000 to $5,000,000 est. value
Syracuse, NY 13210

Mechanical Maintenance of TU-3
Term Contract
Results
Syracuse, NY 13210

Exhaust Duct and Dryer Vent Cleaning Services
Post-Bid
Syracuse, NY 13210

Baldwinsville WWTP HVAC Improvements
Results
Baldwinsville, NY 13027

HVAC Inspection and Repair Services
Term Contract
Post-Bid
Syracuse, NY

Furnish HVAC Filters as Specified
Term Contract
Results
NY

J041--Cooling Tower Fill Service for Syracuse VA 528A7 VHA Directive 1193
Term Contract
Post-Bid
Syracuse, NY 13210

Medical Library HVAC Modifications
Alteration
Results
Syracuse, NY 13210

Last Updated 10/14/2021 09:59 AM
Project Title

Furnish Brewerton WWTP Gallery Fan Replacement Project

Physical Address View project details and contacts
City, State (County) Brewerton, NY 13029   (Onondaga County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Results
Bids Due View project details and contacts
Estimated Value
Plans Available from
Owner View project details and contacts
Architect View project details and contacts
Description

The scope of work for this project will include the replacement of two (2) air supply fans for the gallery and (2) exhaust fans for the gallery. The work will include removal, disposal and replacement of the existing fans, dampers and drip pans and replacement of these items with new. All duct work and electrical work will be included as necessary to complete the installation. Work involves the replacement of four (4) fans, two exhaust and two supply fans on the aeration deck of the Brewerton WWTP. The work will include the removal and demolition of the existing fans. Contractor shall include in the bid necessary electrical work to disconnect the existing louver and fan motor and reconnect the new items once completed. No other control work is expected. Furnish and install new galvanized duct drop and interlocked automatic air damper from supply and exhaust fan into the existing space. Furnish and install 2 new galvanized drip pans in the gallery space at each supply fan to match the existing configuration. Contractor shall be responsible for taking all measurements necessary to insure the proposed fans are compatible with existing curbs, that the proposed motorized dampers are compatible with the existing openings and all necessary clearances are maintained. Any and all modifications to accommodate the new equipment shall be included in the bid price

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents