Similar Projects
Relocated Airfield Electrical Vault
Bidding
$3,211,905 est. value
Clearwater, FL 33762

Construction of Electrical Underground Project
Bidding
Saint Pete Beach, FL

Marine Mammals Pathology Lab Generator Replacement
Term Contract
Post-Bid
Less than $150,000 est. value
Saint Petersburg, FL 33711

Construction Manager for the FIU MMC PG5 Generator Addition
Post-Bid
Belleair, FL

Interior Lighting Upgrades
Results
Less than $60,000 est. value

Generator, Mobile, 80KW
Results
Less than $75,000 est. value
Largo, FL 33779

Transfer Switchgear
Bidding
Tarpon Springs, FL

UPS Systems and Batteries - Purchase, Warranty-Replacement and Maintenance
Post-Bid
Clearwater, FL 33756

Pump Station Generator Improvements (PID #003762A)
Results
$3,800,344 to $3,978,777 est. value
Clearwater, FL 33755

Generator System Addition
Bidding
Palm Harbor, Saint Petersburg, FL 34683

City Post, Surface Mount
Post-Bid
Saint Petersburg, FL 33731

J--Service: Lightning Protection Systems Repairs
Results
Bay Pines, FL 33744

Yaskawa Variable Frequency Drives
Bidding
Clearwater, FL 33759

Testing and Repair of Hydroelectric Generator Governor Systems at Hydroelectric Facilities for the U.S. Army Corps of Engineers
Post-Bid

Stand-by Generators
Results
Largo, FL 33779

Reported 03/24/2021 12:00 AM
Project Title

Preventative Maintenance of LV Breakers and Switches

Physical Address View project details and contacts
City, State (County) FL   (Pinellas County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Request for Quotations
Bids Due View project details and contacts
Estimated Value
Plans Available from County Agency
Owner View project details and contacts
Architect View project details and contacts
Description

1. All breakers and switches shall be cleaned and inspected for evidence of damaged or defective devices. 2. All circuit breakers and switches shall be manually operated and inspected for proper open and close operation. 3. The primary contact resistance of each phase shall be measured with a ductor and recorded. 4. The circuit breakers equipped with solid-state overcurrent trip devices shall be tested with their respective factory test sets. 5. The test data obtained shall be included as part of the Engineering Report and provided to the Facility Manager.

Details

Division 26 - Electrical, Medium-Voltage Switchgear, Medium-Voltage Circuit Breaker Switchgear, Low-Voltage Circuit Protective Devices, Enclosed Switches and Circuit Breakers, Enclosed Circuit Breakers, Transfer Switches.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents