Similar Projects
Fire Rescue Station 15 - Bay Door Replacement
Alteration
Bidding
Juno Beach, FL 33408

Doors, Double, Furnish and Installation
Alteration
Bidding
West Palm Beach, FL 33401

Overhead Doors, Maintenance and Repair Services
Term Contract
Post-Bid
West Palm Beach, FL 33415

Hurricane Shutter Maintenance and Activation
Term Contract
Post-Bid
West Palm Beach, FL

Town Hall Door Restoration/Replacement
Results
West Palm Beach, FL 33403

PBC Convention Center - Exhibit Hall Door Reconditioning
Results
West Palm Beach, FL 33401

Fire Rescue Station 68 - Bay Door Replacement
Post-Bid
West Palm Beach, FL 33403

Fire Rescue Station 21 - Bay Door Replacement
Results
Loxahatchee, FL 33470

Removal of Existing and Furnish and the Installation of a New Fiberglass Door
Alteration
Post-Bid
West Palm Beach, FL 33413

Remove and Install Concession Stand Doors at Olympia Park and Tiger Shark Cove Park
Results
Wellington, FL 33414

Neil Kirkman Building - Automatic Door Openers
Alteration
Post-Bid

Doors, Mechanical, Maintenance / Repair of
Term Contract
Results
West Palm Beach, FL

Impact Doors and Windows
Alteration
Post-Bid
Jupiter, FL 33478

PBC Convention Center - Hollow Metal Door Replacement
Term Contract, Alteration
Results
West Palm Beach, FL 33401

Fire Rescue Station #30 - Bay Door Replacement
Alteration
Post-Bid
Wellington, FL 33414

Reported 04/15/2022 12:00 AM
Project Title

Fire Rescue Station 48 - Bay Door Replacement

Physical Address View project details and contacts
City, State (County) Lake Worth, FL 33467   (Palm Beach County)
Category(s) Single Trades
Sub-Category(s) Windows/Doors
Contracting Method Competitive Bids.
Project Status Bidding
Bids Due View project details and contacts
Estimated Value
Plans Available from County Agency
Owner View project details and contacts
Architect View project details and contacts
Description

a. Remove and properly dispose of four (4) overhead bay doors, including all appurtenances. Reference Exhibits “1” - “6” for replacement requirements b. Execute work in a manner to protect adjacent equipment and other existing items against damage. c. Disconnect electrical power, entrapment protection, push-button and remote control connections. d. Remove complete overhead door assembly to include panels, track, rollers, motor, torsion shaft assembly, trolley and push-button controls. All removed components shall be properly disposed of away from the property each day. All overhead doors are to be replaced by the end of the day so that the openings are not left open overnight. e. Furnish and install four (4) new overhead bay doors, Stormtite 625 Series Insulated Service Door (or PBC approved equal) reference Exhibit “1”. f. Install new overhead door assembly to include new track, rollers, operating motor, and trolley assembly, torsion shaft assembly with new spring, hinges, and fixtures; reference Exhibit “2”. g. Connect power supply, all push button controls to the corresponding door. Install and connect new remote control units and install entrapment protection assemblies. h. Coordinate installation of electrical service. Complete power and control wiring from disconnect to unit components. i. The master (emergency) lift button on the wall must be connected to all doors for emergency engine response as it is now. This must be tested after each new door is installed.

Details

Division 08 - Openings, Doors and Frames, Windows.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents