Correct Electrical Deficiencies (HS)
Design
$500,000 to $1,000,000 est. value
Hot Springs, SD 57747

Replace Generator
Term Contract
Design
Keystone, SD 57751

Transformers - Electric Department
Alteration
Bidding
Watertown, SD

SDDC Decentralization Phase 1
Alteration
Bidding
$1,200,000 est. value
Redfield, SD

Animal Science Complex Transformer Replacement
Post-Bid
Brookings, SD 57006

Scheduled Maintenance for Onan Generators
Post-Bid
Rapid City, SD

Substation Testing and Maintenance
Results
Sioux Falls, SD

Generator with Gas Line, Electrical Line, and Concrete
Results
SD

Installation of LED Replacement Heads
Alteration
Bidding
Sioux Falls, SD

Minute Man Missile Site - Replace Cathodic Protection System Components
Post-Bid
$25,000 to $100,000 est. value
Philip, SD

Pad-Mounted Transformers
Results
Sioux Falls, SD

Microfiber and Microduct Conduit
Infrastructure
Bidding
Sioux Falls, SD

State Fair Freedom and Dakotaland Stage Sound/Light
Post-Bid
Huron, SD

Kones And Booster C Generator
Renovation
Results
$200,000 est. value
Watertown, SD 57201

LED Light Fixtures Annual
Term Contract
Post-Bid

Reported 10/18/2021 12:00 AM
Project Title

Emergency Generator Annual Load Bank Testing And Semi-Annual Maintenance And Testing Services

Physical Address View project details and contacts
City, State (County) Fort Meade, SD 57741   (Meade County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Accepting Letters of Interest
Bids Due View project details and contacts
Estimated Value
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Provide semi-annual preventive maintenance inspections and services on emergency generators at the VA medical Centers at Ft Meade and Hot Springs, South Dakota. The Contractor shall inspect and service in accordance with the manufacturer’s recommendations, prevailing industry standards and local, state, national, and international (where applicable) codes. Annual Load Bank Testing included in Attachment A will be accomplished in accordance with NFPA. The testing shall be documented, and supplemental loads included at 25 percent of the name plate rating for 30 minutes. Followed by 50 percent of the nameplate rating for 30 minutes. Followed by 75 percent for 1 hour. All emergency generators will be load bank tested annually. This work may need to be partly outside of standard VA business hours to minimize patient impact. Supplies, fluid testing, filters, fluids (for top off for the semi-annual PMs) will be supplied by the contractor. Contractor is to diagnose other or larger problems and present quote to the POC for approval, before additional work is conducted. Smaller repairs (Belts, hoses, batteries, leak repair), with approval from POC, can be conducted with Credit Card payment from POC. Fluid testing will need to be conducted by 3rd party tester semiannually. And reported made to POC within 30 days of service. Contractor should provide priority for repairs to the BHHCS VA Emergency Generators and ATS Switches.

Details

Division 26 - Electrical.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents