Reported | 03/28/2020 12:00 AM |
Project Title | Hammond West Terrace Water Proofing |
Physical Address | View project details and contacts |
City, State (County) | Hammond, IN 46320 (Lake County) |
Category(s) | Single Trades |
Sub-Category(s) | Finishes/Exterior |
Contracting Method | Competitive Bids. |
Project Status | Accepting Letters of Interest |
Bids Due | View project details and contacts |
Estimated Value | $1,000,000 to $5,000,000 |
Plans Available from | Federal Agency |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | The work includes but is not limited to: 1. Remove and Storage of the existing Plaza Paver System 2. Removal and disposal of the existing plaza waterproofing membrane, associated flashings and insulation 3. Removal and disposal of the existing planter boxes foliage 4. Removal and disposal of the existing planter boxes growing medium 5. Removal and disposal of the existing planter boxes waterproofing membrane and associated flashings 6. Removal and disposal of the existing roof drain body assemblies 7. Removal and disposal of the existing planter boxes' drain assemblies 8. Disassembly, cataloging and storage of the limestone cladding units to the extent necessary to expose, remove and install termination flashings per the design intent 9. Disassembly, cataloging and storage of copings to remove failed flashing 10. Installation of a new waterproofing roofing membrane, associated flashings and insulation per the design intent 11. Installation of a new planter box waterproofing membrane 12. Installation of a new drainage assembly per design for the roof system 13. Installation of a new drainage system for the planter boxes. 14 Installation of coping flashings 15. Installation of waterproofing terminations at the roof-to-wall interfaces at all locations 16. Reinstallation of limestone cladding after flashing and terminations have been inspected for conformance. Stones must be reinstalled in the same location and direction prior to the removal 17. Reinstallation of the coping stones once new flashing has been installed and inspected for conformance. 18. Reinstallation of all sealant per the design 19. Removal of window sealant as designated 20. Removal of failed window flashings 21. Installation of new window flashings 22. Installation of sealant system at window assemblies 23. Removal, cleaning 24. Removal and repair reconstruction of interior drywall bulkhead at lower level plaza 25. Removal and replacement of ceiling panels of interior lower level plaza due to water inflation damage and staining 26. Removal of existing at-grade gate system. 27. Installation of temporary security at removed at-grade gate system 28. Cleaning, preparing, priming and painting of existing at-grade gate system 29. Reinstallation, balancing and adjusting of at-grade gate system. 30. Address door thresholds that interface with the roofing waterproofing and flashings 31. Address window sills, flashing and sealants as they relate to the waterproofing system and provide continuation of the window waterproofing system 32. All materials must be stored at a secure location in a manner not to damage the facility 33. Interior spaces and site cleaning restoration 34. and all necessary ancillary work to complete the project as specified and designed. 35. Contractor is responsible for providing a workforce that can obtain special security clearance necessary by GSA and the Courts. 35. Provide all warranties, record document markups and operations and maintenance system documentation 36. Contractor shall provide all other necessary construction and administration services to complete per the GSA P100 Standards and the project's design and specifications. 37. Concrete Deck Repairs. |
||||||||||
Details |
|
||||||||||
Bidder's List | View project details and contacts | ||||||||||
Prospective Bidders | View project details and contacts | ||||||||||
Project Documents |