Similar Projects
Reported | 03/29/2022 12:00 AM |
Project Title | Leaky Coax Cable Rerouting and Installation |
Physical Address | View project details and contacts |
City, State (County) | Loma Linda, CA 92354 (San Bernardino County) |
Category(s) | Single Trades |
Sub-Category(s) | Security/Communications |
Contracting Method | Competitive Bids. |
Project Status | Request for Quotations |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | Federal Agency |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | Rerouting an existing Leaky Coax Cable and the installation of a new Leaky Coax Cable is necessary to improve communications between VA Loma Linda Medical Center (VALLMC) and the San Bernardino County Police Department. Various construction projects in the main Hospital throughout the year removed Leaky Coax cabling, creating dead zones throughout the facility. This has resulted in the hospital s inability to communicate effectively with the San Bernardino County Police Department. OBJECTIVES: Contractor shall provide all Supervision, labor, transportation, materials, tools, supplies, and equipment to accomplish the following: Reroute existing 250-foot long RXL4 Generic Radiating Leaky Coax Cable that begins in the interstitial above Service Bay 3, room SB01-3A and ends in the interstitial near Rm 1C-25C [See drawing B (Yellow line)]. After cable is removed, it shall be reinstalled and connected to an existing Leaky Coax Cable in the interstitial above corridor C107. The cable follows the interstitial above the C107 corridor to the C1-05 corridor until it terminates at the antenna located in the dropped ceiling outside Room IA-260, Emergency Department s Nurses Station [See drawing B, (Orange Line)]. Install new 600-foot RXL4 Generic Radiating Leaky Coax cable beginning at the interstitial above IT Closet 1E-75 (see drawing A (Purple box)], through the Community Living Center Rehabilitation Unit above the dropped ceiling in corridors 1H03, 1H06, and 1H20, then over to the Community Living Center Palliative Care Unit above the dropped ceiling in corridor C1-142, ending above the dropped ceiling outside of rooms 1G-101and 1G-102. [See drawing A (Red line). Install conduit sleeves for all cabling that penetrates fire rated walls. Installation of fire proofing material [3M Fire Barrier (CP 25WB+, color Red)] shall be thoroughly and neatly place in and around conduit sleeves and openings as required, preserving the integrity of the fire stopping system s integrity and rating. VA Loma Linda Engineering Services will supply the 250-foot and 600-foot cables. PERIOD OF PERFORMANCE: 30 Calendar days. Work will be done on a weekday or weeknights (i.e., Monday thru Friday during the day, Saturday, and/or Sunday during the day) (starting at 6am to 5pm for days or 6pm to 5am for nights due to the requirement of load demand). Work will be coordinated with COR. |
||||
Details |
|
||||
Bidder's List | View project details and contacts | ||||
Prospective Bidders | View project details and contacts | ||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |