Similar Projects
Last Updated | 09/02/2020 11:04 AM |
Project Title | Lighting Repairs and Improvements in the Central Artery Tunnel (I-93) (CRC 17D and 17F) |
Physical Address | View project details and contacts |
City, State (County) | Boston, MA 02108 (Suffolk County) |
Category(s) | Outdoor Lighting |
Sub-Category(s) | Roadway Lighting |
Contracting Method | Competitive Bids. |
Project Status | Results |
Bids Due | View project details and contacts |
Estimated Value | $26,224,000 |
Plans Available from | |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | "1.000","Ls","Schedule Of Operations - Fixed Price $117,500","100." "672.000","Sf","Clean And Paint Structural Steel","106.302" "440.000","Sf","Replacement Of Cementitious Fireproofing","107.996" "1630.000","Sf","Replacement Of Rigid Board Fireproofing","107.997" "1.000","Ls","Inspection And Testing For Asbestos","182.1" "816.000","Sf","Removal Of Asbestos","182.25" "6086.000","Ea","Disposal Of Mercury Containing Lamps","183.3" "1.000","Ls","Removal Of Luminaires And Wireway","188.6" "33.000","Mo","Engineers Field Office And Equipment (Type a)","740." "1.000","Ls","Mobilization","748." "4514.000","Ft","1-1/2 Inch Xw Phenolic Conduit","804.151" "48037.000","Ft","2 Inch Xw Phenolic Conduit","804.21" "595.000","Ft","3/4 Inch Electrical Conduit Type Rm - Galvanized Steel","806.075" "2704.000","Ft","3 Inch Electrical Conduit Type Rm - Galvanized Steel","806.3" "11868.000","Ft","3/4 Inch Electrical Conduit - Flexible Metallic","809.075" "333.000","Ea","Emergency Junction Box","811.58" "1709.000","Ea","Nema 4x 316ss Junction Box","811.59" "1.000","Ls","Electrical Testing Of Existing Conductors","813.001" "10242.000","Ft","Wire Type Xhhw-2 No. 12","813.029" "407415.000","Ft","Wire Type Xhhw-2 No. 10","813.030" "95850.000","Ft","Wire Type Xhhw-2 No. 8","813.031" "237650.000","Ft","Wire Type Xhhw-2 No. 6","813.032" "223950.000","Ft","Wire Type Xhhw-2 No. 4","813.033" "132350.000","Ft","Wire Type Xhhw-2 No. 3","813.034" "247700.000","Ft","Wire Type Xhhw-2 No. 2","813.035" "83000.000","Ft","Wire Type Xhhw-2 No. 1","813.036" "1998.000","Ft","2-Hour Fire Rated Cables - Emg Ckts Only (No. 12)","813.129" "26514.000","Ft","2-Hour Fire Rated Cables - Emg Ckts Only (No. 10)","813.130" "13880.000","Ft","2-Hour Fire Rated Cables - Emg Ckts Only (No. 6)","813.132" "9210.000","Ea","Wire Splicing In Junction Box","813.361" "1332.000","Ea","Emergency Connectors","813.363" "1760.000","Ea","Mc Cable Splicing In Junction Box","813.364" "1344.000","Ea","Led Luminaire - 151 Watts - Ceiling Mount (s1 & n1)","823.01" "195.000","Ea","Led Luminaire - 182 Watts - Wall Mount(s2)","823.02" "36.000","Ea","Led Luminaire - 262 Watts - Ceiling Mount(s3)","823.03" "84.000","Ea","Led Luminaire - 345 Watts - Ceiling Mount(s4)","823.04" "516.000","Ea","Led Luminaire - 435 Watts - Ceiling Mount(s5 & n3)","823.05" "136.000","Ea","Led Luminaire - 321 Watts - Ceiling Mount(s6 & n2)","823.06" "1.000","Ls","Tunnel Lighting Control System","823.541" "1.000","Ls","Plc Retrofit Cabinent","823.545" "284.000","Ea","Structural Lighting Support - Type d","960.200" "90.000","Ea","Structural Lighting Support - Type d1 ","960.201" "78.000","Ea","Structural Lighting Support - Type h","960.300" "30.000","Ea","Structural Lighting Support - Type h1","960.301" "6.000","Ea","Structural Lighting Support - Type h2","960.302" "6.000","Ea","Structural Lighting Support - Type h3","960.303" "84.000","Ea","Structural Lighting Support - Type h4","960.304" "1.000","Ea","Structural Lighting Support - Type c1","960.401" "80.000","Ea","Structural Lighting Support - Type w1","960.500" "107.000","Ea","Structural Lighting Support - Type w2","960.501" "1.000","Ls","Channel Spring Nut Replacement","960.600" |
||
Details |
|
||
Bidder's List | View project details and contacts | ||
Prospective Bidders | View project details and contacts | ||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |