Similar Projects
4.1 miles Fire Control Line
Alteration
Bidding
Santa Fe, NM

Fire System Equipment, Installation, Inspection, Maintenance and Training
Post-Bid
Albuquerque, NM 87102

Fire Detection Systems Repair
Post-Bid
Shiprock, NM

FFO Fire Suppression Systems Inspection
Results
Farmington, NM

Solid Waste Facility Fire Suppression Project
Results
Las Vegas, NM 87701

Fire Alarm and Sprinkler System Testing
Post-Bid
Gallup, NM 87301

Fire Extinguisher and Fire Alarm Inspection
Results
Shiprock, NM 87420

Gallup Service Unit: Fire Alarm & Sprinkler Systems
Post-Bid
Gallup, NM

UNM Annual Fire Alarm Elevator Support
Term Contract
Results
Albuquerque, NM 87131

Fire Detection System Installation
Post-Bid
Albuquerque, NM 87196

Firearm Maintenance and Repair
Term Contract
Results
Santa Fe, NM 87505

Fire and Security Systems IDIQ- Plains Area - South
Post-Bid

GSD Fire Extinguishers Maintenance and Service
Term Contract
Results
Santa Fe, NM 87505

Fire Alarm System Replacement
Post-Bid
Chinle, Fort Defiance, Kaibito, Kayenta, Sanders, Tuba City, AZ - Crownpoint, NM

Restoration and Repair Services - As Needed
Results
Albuquerque, NM

Reported 03/11/2022 12:00 AM
Project Title

Crownpoint Outpatient Treatment Center Fire Alarm Systems Inspection, Repair, Replace or Install Project (3 buildings)

Physical Address View project details and contacts
City, State (County) Crownpoint, NM   (McKinley County)
Category(s) Single Trades
Sub-Category(s) Fire Protection
Contracting Method Competitive Bids.
Project Status Request for Proposals (RFPs)
Bids Due View project details and contacts
Estimated Value
Plans Available from State Agency
Owner View project details and contacts
Architect View project details and contacts
Description

The Division of Behavioral and Mental Health Services (DBMHS) is requesting installation and inspection services for the non-existent fire alarm control panel system at the Crownpoint Outpatient Treatment Center. It is the intent of DBMHS to bring all fire alarm systems up to date and in compliance with building and life safety codes. The vendor must be licensed as a commercial fire safety inspection company. Location: Crownpoint DBMHS Administration, Crownpoint, NM Building Property # (none) Approximately 2,044 sq. ft. This project may entail the following: 1. Install an addressable fire alarm control panel and components (including but limited to back up batteries, relay modules; pull station; smoke detector; interior horn alarm; exterior horn alarm; interior horn/strobe). 2. Provide as-built drawings as the fire protection plan. 3. Connect to a 24/7 monitoring company and test. 4. Recommendation of special fire suppression systems in the DBMHS Data room for sensitive computer and other electronic equipment. 5. Inspect and certify two (2) fire extinguishers to include recharge/ rebuild if needed per NFPA 10. 6. Inspect and certify two (2) exit lighting and emergency exit lighting and signage. 7. Inspect and certify two (2) exit doors with panic release hardware (in good working order). 8. Location, ownership and testing of nearest public fire hydrant. 9. Provide Project Manager with detailed Inspection reports and language that can be utilized for the development of a scope of work for each site for repairs, replacement or additions, if necessary. This report should include proposed costs. 10. Annual inspections of all mentioned systems for five (5) years to ensure proper operations of all systems and components. 11. Upon completion of inspection services, minor repairs equal to or less than One Thousand Dollars ($1,000.00) allowance per year per building (this is included to the cost proposal). 12. Provide all materials (operating/maintenance manuals) and workmanship warranty information to site. 13. Provide operating and maintenance/training information to project manager and site staff 14. Contractor is responsible for field verification of systems at all sites. 15. Cost details breakdowns are to include labor, equipment, materials, minor repairs allowance, travel expenses and the Navajo Nation Tax of 6%. Please be cognizant that the grand total is the contract total. 16. Exclusions: Based on your expertise- please list any and all fire related life safety code requirements not otherwise in this scope of work. (Do not list costs with main proposal).

Details

Division 21 - Fire Suppression.
Division 28 - Electronic Safety and Security, Fire Detection and Alarm.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents