Similar Projects
Reported | 05/16/2020 12:00 AM |
Project Title | 6515-- Endoscope Drying Cabinets |
Physical Address | View project details and contacts |
City, State (County) | Philadelphia, PA 19104 (Philadelphia County) |
Category(s) | Single Trades |
Sub-Category(s) | Furnishings |
Contracting Method | Competitive Bids. |
Project Status | Accepting Letters of Interest |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | Federal Agency |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | Project Scope/Specifications/Installation- Sterile Processing requires two scope cabinets with the following features: The ability to utilize the Medivator cassette directly into the scope drying cabinet. This will prevent damage and contamination after the scopes have been reprocessed. Provide sensors and gauges or lights that will monitor the dampness of the scopes until they are completely dry. One such cabinet uses RED, AMBER, GREEN lights. A monitor that tracks the 12-day hangtime for each scope. This will ensure that no scope is distributed or used after the 12th day. After that date, the scope needs to be reprocessed through the Medivator. Eight endoscope trays with interlocks Barcode reader for consistent data entry, endoscope tracking and user authorization Programmable maximum storage time Alarm in case of pressure or power loss Internal digital documentation of process parameters Integrated multi-lingual information and control panel CANEXIS Software network-compatible Available in single-sided configurations pass-through configurations Utilizes hands-free scope handling system for HLD, drying, storage and transport Additional Specifications required: Air Supply The cabinet must use compressed air in accordance with ISO 8573-1:2010, class 1.4.1. The required air pressure is 29-116 psi (2-8 bar). The demand of compressed air is a maximum flow rate of 3.4 cfm (95 l/min) (ANR) and 0.6 cfm (16 l/min) @ 72 psi (5 bar). A flexible air pipe with ¼ or 6 mm inner diameter (EPDM/PVC, bound, 150 psi minimum (10.5 bar) minimum length 5 feet (1.5m)) Electrical Supply 100-240 VAC ± 10%, single phase, 50/60 Hz, 15 amp circuit Power input: 75W A GFI protected outlet (NEMA 5-15R) within 3 feet (1 meter) of the installation and within reach of the operator. Install a surge protector to protect the Storage and Drying System from voltage spikes. Spacing and Flooring Self-containing leveling pads should be adjusted during installation. For optimal user-safety and operation, it is recommended that the Storage and Drying System always be placed directly on the floor, and not on an elevated platform type device. Dimensions: H75 X W24 X D22 (190cm x 60cm x 54cm) Weight: 375 lbs (170 kg) Remote Access If applicable, the control system of the Storage and Drying System can be connected to an ADVANTAGE PLUS® Automated Endoscope Reprocessor(s) or a computer by LAN interface (1xRJ45, 10/100 Mbit) and be operated by a remote client. A network connection to an ADVANTAGE PLUS AER allows for the transfer of operator and endoscope information. Trade in Allowance The vendor shall offer a trade in allowance for two Stanley innerspace cabinets product #38600AA. |
||
Details |
|
||
Bidder's List | View project details and contacts | ||
Prospective Bidders | View project details and contacts | ||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |