Similar Projects
HVAC Services - All Schools
Term Contract
Sub-Bidding
$180,000 CJ est. value
Billerica, MA 01821

HVAC Services
Term Contract
Sub-Bidding
Billerica, MA 01821

HVAC Maintenance Services
Term Contract
Post-Bid
$300,000 est. value
Tyngsborough, MA

Furnish Outdoor Air System
Alteration
Post-Bid
Lowell, MA

Scheduled and Emergency HVAC System Repairs and Improvements at Various Locations
Results
$127,050 est. value

Bathroom Exhaust Fans, Tannerville 667-1 & 667-2 - General Bids
Alteration
Results
$196,000 est. value
Reading, MA 01867

Police H.V.A.C. Repair Project
Renovation
Construction
$89,932 CJ est. value
North Reading, MA 01864

Capen Court - Senior housing (667-1) Chiller Replacement
Renovation
Construction
$234,300 CJ est. value
Somerville, MA 02144

Kitchen Remodel & Upgrade at McCarthy Middle School - Sub
Renovation
Sub-Bidding
$500,000 CJ est. value
Chelmsford, MA 01824

Annual Maintenance and Service HVAC and Plumbing Systems
Term Contract
Post-Bid
$240,000 est. value
Boston, Dedham, Everett, Newton, Revere, Somerville, MA

Masonic Hall Town Hall Chiller and Other Projects
Alteration
Results
$2,000,000 est. value
Billerica, MA

Purchase and Delivery of One (1) Air Handling Unit and One (1) Air Cooled Condensing Unit
Alteration
Post-Bid
Lexington, MA 02421

Replacement of a Rooftop 35 Ton HVAC Unit
Alteration
Results
$150,000 est. value
Littleton, MA 01460

Air Cooled Chiller
Alteration
Post-Bid
Lexington, MA

FMC Devens- Water Treatment Services
Term Contract
Results
Ayer, Devens, MA 01434

Last Updated 05/10/2023 10:09 AM
Project Title

Rooftop Unit Replacement

Physical Address View project details and contacts
City, State (County) Westford, MA 01886   (Middlesex County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids
Project Status Sub-Bidding, Construction start expected June 2023
Bids Due View project details and contacts
Estimated Value $275,000 [brand] Estimate
Plans Available from Agency's Affiliate - 04/19/23
Owner View project details and contacts
Architect View project details and contacts
Description

replacement of a Rooftop HVAC system at Nashoba Valley Technical High School (NVTHS) Description of Work Each Bidder shall carefully examine the site, engineering drawings and the information available to provide the services and all conditions which may affect proper execution of this agreement. The purpose of this agreement is to provide the District with services and products as detailed in these specifications in accordance with all applicable federal, state, and local statutes, laws, and regulations. No claims for additional costs will be allowed because of lack of knowledge of the existing conditions. Bids shall include all services and all other costs to complete this agreement as specified herein. Furnish and install a new HVAC system, including removal of the existing rooftop unit. Please consult drawing M1.01 and specification sheets for details; alternate manufacturers with equal or better specifications will be considered. Units to be installed consist of: 1 - Energy Recovery Ventilator Unit 1 - Outdoor Air Cooled Condensing Unit 5 - Indoor Air Conditioning Units Controls and integration to existing Niagara management control system A. Contractor to remove existing unit from the roof. B. Contractor to make any alterations to the existing curb if needed. C. Any penetrations to roofing must be done by Carlisle-certified roofers (roof is under warranty) and approved by NVTHS facilities director. D. Contractor to place rooftop condensing unit in consultation with NVTHS facilities director. E. Install a 120v GFCI weatherproof receptacle at the unit. This receptacle can be separate or integrated with the unit. F. Mount a 120v GFCI weatherproof light fixture at the unit. G. Install Power and Control wiring. H. Install inline smoke detector and CO detector. Both shall shut down the unit if activated. Smoke detector to report to the Fire Alarm panel. CO detector to report back to the BacNet system. I. Contractor to provide all controls (e.g. thermostat) to operate with the existing Niagara Control console and BacNet system. J. Unit shall be installed with a permanent plate labeled per NVTHS instruction. K. Reconnect new Unit to new Supply and Return Ductwork. L. Contractor to field measure and determine additional supply/return ductwork to ensure adequate airflow. M. New ductwork as needed per drawing. Ductwork to be insulated. N. Insulate existing supply trunkline. O. Supply new Diffusers. P. Start Up and Test the new unit. Q. Unit MUST be compatible, connected and configured to work with the existing DDC control system.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents