Similar Projects
Replace High Voltage Switchgear
Alteration
Design
$2,000,000 to $5,000,000 est. value
Queens, NY 11434

Electrical Upgrade
Term Contract
Design
Less than $25,000 est. value
Staten Island, NY 10305

Provide Generator Radiator Shroud - Green Haven CF
Bidding
$250,000 to $500,000 est. value
Stormville, NY

Electrical Improvements at Wells 3 & 4
Infrastructure, Alteration
Bidding
Carle Place, NY

Albany Public Library Howe Branch Solar PV and Generator
Post-Bid
Albany, NY 12210

J059--Uninterruptible Power Supplies (UPS) Preventative Maintenance
Post-Bid
Canandaigua, NY

J--Testing & PM for Generator Systems - Buffalo/Batavia
Results
$100,000 to $250,000 est. value
Batavia, Buffalo, NY 14215

J--Testing & PM for Generator Systems - Buffalo/Batavia
Results
$100,000 to $250,000 est. value
Batavia, Buffalo, NY 14215

Dioxane and Nitrates, Levittown in Wells 1A and 2A in the Levittown Water District- Electrical Construction
Alteration
Bidding
East Meadow, NY 11554

MOC Emergency Generation Upgrades
Term Contract
Post-Bid
Oneonta, NY

Z1DA--528A6-20-629 Upgrade Electrical Loop
Results
$250,000 to $500,000 est. value
Bath, NY 14810

Generator Annual Testing and Corrective Repair Service
Term Contract
Bidding
Brooklyn, Queens, NY 11209

Provide Recording Room and Facility Wide CCTV / Audio and Civilian Personal Alarm System - Electrical Work
Post-Bid
$15,000,000 to $20,000,000 est. value
Fishkill, NY 12524

UH2 Extend Generator Exhaust
Results
Syracuse, NY 13210

Highway Garage Rooftop Solar System
Post-Bid
Red Hook, NY 12571

Reported 02/25/2022 12:00 AM
Project Title

Electrical Switchgear Testing at Groveland Correctional Facility

Physical Address View project details and contacts
City, State (County) Sonyea, NY 14556   (Livingston County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Bidding
Bids Due View project details and contacts
Estimated Value
Plans Available from State Agency
Owner View project details and contacts
Architect View project details and contacts
Description

The facility is powered via two (2) incoming 13.2kV Utility electrical services. The incoming switchboard consists of (13) Eaton VCP-W vacuum circuit breakers. Protection is provided via (13) Eaton FP-5000 protective relays. Backup Power is provided by (2) 13.2kV generators. The generator switchboard consists of (4) 13.2kV Square D Type VR vacuum circuit breakers. Protective relays consist of (4) General Electric Type 489 relays and (3) General Electric Type PQMII Meters. There are two (2) Battery Systems: 48V Battery System: (38) ALCAD HC-11 OP Ni-Cad. 125V Battery System: (92) GA2 KM 140P Ni-Cad. (26) Pad mounted switchgear. (9) Non-automatic transfer switches. All equipment is to be serviced using this listed scope of work. Contractor to provide generators and connect to critical buildings to maintain power during service. This may have to be done during off hours (to be coordinated by the facility). Install UL listed Infra-Red windows in the incoming switchgear cabinets.

Details

Division 26 - Electrical, Medium-Voltage Switchgear.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents