Similar Projects
Last Updated | 07/20/2023 02:06 AM |
Project Title | Deliver & Install Brand Name or Equivalent HVAC |
Physical Address | View project details and contacts |
City, State (County) | Athens, GA 30605 (Clarke County) |
Category(s) | Single Trades |
Sub-Category(s) | HVAC |
Contracting Method | Competitive Bids |
Project Status | Sub-Bidding, Construction start expected September 2023 |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | Agency's Affiliate |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | Deliver and install Brand name or equivalent Liebert Minimate 2 Precision Cooling System. Deliver and install Brand Name or Equivalent Liebert Minimate 2 Precision Cooling System. Deliver and install within 30 days after award to: U.S. EPA, Region 4, Laboratory Services and Applied Sciences Division (LSASD), 980 College Station Road, Athens, GA 30605 (for PM2.5 PEP national weigh lab). Power unit down, and recover and recycle refrigerant from system. -Disconnect high voltage and low voltage wiring from indoor and outdoor unit. -Disconnect refrigerant piping, drain piping. -Remove and dispose of old indoor and outdoor units. -Install new indoor unit above ceiling, and install new condensing unit on roof. -Reconnect all electrical and piping to new unit. -Evacuate system and charge with new R407C refrigerant. -Start new system up and fill out warranty inspection report. -Work to be performed during normal business hours (9:00 am - 5:00 pm). -(Quantity 1 each) 1.5 Ton Liebert Mini-Mate2 Precision Cooling System includes: - Each system will provide a total cooling capacity of __ kBtuh and a sensible cooling capacity of ___ kBtuh at 75F (24 C), 45% RH. - Unit configured for input voltage of 208/230 Volts, 1 Phase, 60 Hz Split System - Includes evaporator coil, filter-drier, thermal expansion valve, two-speed blower assembly, and microprocessor control with audible and visual alarms Factory Installed Options - Cooling Unit - SCR Reheat. - Canister Humidifier with a capacity of 2.5 lbs/hr (1.14 kg/hr) - Compliance with ASME A112.1.2 section 2.4.2 (backsiphonage testing) - Remote Humidifier Contact - Non-Locking Disconnect Switch - Filter Clog Indicator - High Temperature Sensor - IS-UNITY-DP BMS Monitoring Solution: The IS-UNITY-DP card is a factory installed option, providing full building-management system (BMS) access via BACnet/Modbus IP and BACnet/Modbus 485. Card provides access and supports SNMP v1/v2c/v3 & Liebert Nform(TM). Field wiring required from Unity card to other systems to access features. - Ship-Loose Accessories - Quantity One (1) 208/230 Volt Condensate Pump(s) - Quantity One (1) per unit Duct Kit(s) with MERV 8 Filter & Filter Box - Quantity One (1) per unit LT410,Point Leak detection supervised sensor with a painted enclosure that senses a leak via two height adjustable probes. The sensor has two common alarm relay outputs. The sensor requires 24VAC power input. Requisition No: PR-R4-23-00394 |
||
Details |
|
||
Bidder's List | View project details and contacts | ||
Prospective Bidders | View project details and contacts | ||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |