Similar Projects
HVAC System at Manaugh Elementary
Bidding
Cortez, CO 81321

HVAC System at Beech Preschool
Bidding
Cortez, CO 81321

Renovated Air Filtration System
Post-Bid
Rifle, CO 81650

Temperature Monitoring System
Post-Bid
Aurora, CO

ERWSD Administration Building - VRF Renovation (Engineer)
Results
Less than $500,000 est. value
Vail, CO 81657

Air Traffic Control Chillers
Results
Aurora, CO 800119589

Air Conditioner Preventive Maintenance Services
Term Contract
Bidding
Frisco, CO 80443

General Mechanical / Hvac Construction and Preventative Maintenance Services
Post-Bid
Thornton, CO 80229

Repair HVAC Harmon Hall Arnold Hall
Results
$1,000,000 to $5,000,000 est. value
Colorado Springs, CO 80840

Heat Treat Services
Bidding
CO

On-Call Test and Balance For HVAC Systems
Post-Bid
CO

SB267 Upgrade HVAC Systems Group Homes Wheat Ridge Regional Center Phases 1 & 2
Results
$750,000 est. value
Wheat Ridge, CO 80033

Air Handling Units
Bidding
Canon City, CO

IDF Room Cooling
Post-Bid
CO

SB 267 Repair/Upgrade to Mechanical and Electrical Systems
Results
Less than $155,000 est. value
Fruita, CO 81521

Reported 03/23/2021 12:00 AM
Project Title

Sources Sought - Replace Underground HVAC - Meve

Physical Address View project details and contacts
City, State (County) Mesa, CO   (Mesa County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Accepting Letters of Interest
Bids Due View project details and contacts
Estimated Value $500,000 to $1,000,000
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Project to replace a failed underground HVAC heating and cooling circulation system. The existing circulation system is fed by a central heating and cooling plant and serves four separate buildings in a culturally and environmentally sensitive environment located at the park headquarters district. The existing black iron pipe has corroded to the point of failure and will be replaced with a more sustainable, non-metal piping material such as pre-insulated PEX. This project would require demo of approximately 3,500 linear feet of 2¿ to 3¿ black iron piping encased in foam insulation and concrete flow fill and replaced with pre-insulated PEX piping. The current piping is located under a combination of asphalt sidewalk, roadway crossing, and natural earth which would be impacted and needs to be restored and/or replaced. There are also a variety of utility lines, mainly electric and fiber communication, located within the same trench as the existing piping or in the surrounding vicinities which would be required to be protected in place.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents