Similar Projects
Building 200 Wing B2 Renovate VAV Controls
Term Contract
Design
$250,000 to $500,000 est. value
Johnson City, TN 37604

Building 200 Wing B2 Renovate VAV Controls
Term Contract
Design
$250,000 to $500,000 est. value
Johnson City, TN 37604

Communication Tower Microwave Equipment Upgrades
Alteration
Bidding
Gray, Johnson City, TN 37615

RFI - Home Intrusion Detection Systems (CONUS/OCONUS)
Post-Bid

Remotely Piloted Aircraft Squadron Operations Center (RPA SOC) Enterprise
Post-Bid
Robins Air Force Base, GA - Niagara Falls, Syracuse, NY

Force Protection Site Security System Solutions (FPS4) Final Request for Proposal (RFP)
Results
$700,000,000 est. value

National Physical Security (NPSP) Maintenance and Installation
Results
Less than $29,000,000 est. value

Conference Rooms & Office Audio/Visual Equipment & Installation
Post-Bid
Johnson City, TN 37615

Commercial Ethernet Gateway (CEG) - Continental United States (CONUS) Region One
Results

HVAC Replacement
Post-Bid
Jonesborough, TN 37659

Building Automation System (BAS) Installation & Maintenance Enterprise-wide Services
Results

Audio/Visual For Conference Room
Renovation
Post-Bid
Johnson City, TN 37615

Chester Inn HVAC and Building Repairs
Alteration
Results
Jonesborough, TN 37659

ETSU Buc Ridge Buildings P & Q HVAC Upgrades Phase II
Post-Bid
Johnson City, TN 37614

Central Station Alarm Monitoring (CSAM)
Post-Bid

Reported 02/18/2022 12:00 AM
Project Title

Building 200 Wing B2 Renovate VAV Controls

Physical Address View project details and contacts
City, State (County) Johnson City, TN 37604   (Washington County)
Category(s) Single Trades
Sub-Category(s) HVAC, Security/Communications
Contracting Method Competitive Bids.
Project Status Accepting Letters of Interest
Bids Due View project details and contacts
Estimated Value $250,000 to $500,000
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Project 621-22-133: Building 200 Wing B2 Renovate VAV Controls: James H. Quillen VA Medical Center (JHQVAMC) has a requirement to renovate the 26 Variable Air Volume (VAV) controls and add a new VAV box (Room B249) with reheat and DDC controls in Bldg. 200 Wing B2. This project will include removal of the existing pneumatic controls including: the pneumatic actuator on the VAV box, the pneumatic reheat valve, and the pneumatic thermostat. These pneumatic controls will be replaced by direct digital controls (DDC): VAV controller with integrated geared actuator, an electronic geared reheat valve, and an electronic thermostat. These DDC controls will connect to the Mountain Home VAMC’s existing Computrols system.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.
Division 27 - Communications, Common Work Results for Communications.
Division 28 - Electronic Safety and Security, Common Work Results for Electronic Safety and Security.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents