Similar Projects
Office Cleaning Services
Bidding
Lisbon, IL

Cleaning
Term Contract
Bidding
Flora, IL

Naper Settlement Building Cleaning and Artifact Care Support Services
Post-Bid
Naperville, IL

Elgin Community College - Campus Cleaning
Post-Bid
Elgin, IL 60123

Health Department Custodial Services
Term Contract
Results
Peoria, IL 61602

Grounds Maintenance Services
Term Contract
Results
Lake in the Hills, IL 60156

Schiller Place Apartments
New Construction - 33,832 SF
Construction
Chicago, IL 60642

Janitorial Services
Bidding
Bloomington, IL

Custodial Services
Post-Bid
Schaumburg, IL

Janitorial Services
Bidding
Harrisburg, IL

Janitorial Services - Multiple Locations
Term Contract
Post-Bid
Aledo, IL 61231

Custodial Services
Bidding
Urbana, IL

1435 15th Avenue City Owned House Cleanout
Post-Bid
Rock Island, IL 61201

Custodial Services
Bidding
Barrington, IL 60010

Janitorial L5602
Term Contract
Post-Bid
Springfield, IL 62702

Reported 02/19/2021 12:00 AM
Project Title

DFS - Cooling Towers Cleaning

Physical Address View project details and contacts
City, State (County) Belleville, IL 62226   (Saint Clair County)
Category(s) Single Trades
Sub-Category(s) Janitorial/Maintenance
Contracting Method Competitive Bids.
Project Status Bidding
Bids Due View project details and contacts
Estimated Value
Plans Available from State Agency
Owner View project details and contacts
Architect View project details and contacts
Description

The Illinois State Police (ISP) intends to procure cleaning services for four (4) Baltimore Aircoil Company Cooling Towers, Model# FXT-175. Complete cleaning of dirt, debris, and scale from all four (4) cooling towers. Cleaning includes the complete chemical removal of water scale buildup on fill and inner tower walls, remove any obstructions from fill and drift eliminators, inspect and clean dirt and debris from hot and cold-waiter basins, clean dirt and debris from strainer and metering orifices , and flush equalizing line to remove any dirt and debris. Chemical cleaning should utilize non-metal corrosive chemicals capable of removing water scale building without damaging fill, basins, or any other water circulating components. Spray on chemical application to tower is preferred. Replace fan belts, adjust belt tension and check alignment, lubricate fan shaft bearings, check motor insulation.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Cooling Towers.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents