Similar Projects
Delaware County Junior Fair Building Upgrade
Post-Bid
$3,300,000 est. value
Delaware, OH

Utility Monitoring and Control Systems
Post-Bid
Less than $2,100,000,000 est. value

Solon Parkside Elementary and Middle School HVAC Improvements Phase III
Results
$245,000 est. value
Solon, OH

Morehouse Pavilion AHU1 Replacement - Design-Build
Results
$1,216,000 est. value
Columbus, OH

Air Handler Replacements
Post-Bid
Less than $1,500,000 est. value
Dayton, OH

Wilmington High Rise Chiller Replacement
Results
Dayton, OH 45390

Design / Installation - Vehicle Exhaust Removal Systems at Two Fire Stations
Post-Bid
Monroe, OH 45050

Health Department Building Replacement of Package HVAC Unit and Controlling System
Results
Sidney, OH

Exterior Envelope Repairs and HVAC Upgrades of Building 1 at the Cincinnati Job Corps Center, Cincinnati, Ohio
Post-Bid
$1,000,000 to $5,000,000 est. value
Cincinnati, OH 45214

HVAC Unit(s) Installation at Family Support Center 2018.
Results
Batavia, OH

HVAC Rooftop Unit Replacement at Neighborhood Ministries - Rockford Village
Post-Bid
Youngstown, OH

Cuyahoga County Justice Center Complex - CPDHQ Building HVAC System Renovation
Results
Less than $592,494 est. value
Cleveland, OH

Cincinnati VA Medical Center's: Aircuity Optinet System
Post-Bid
Cincinnati, OH 45220

HVAC Maintenance
Term Contract
Results
Springfield, OH

J--Aircuity Service Contract This Sources Sought is Issued to Identify Capable and Interested Vendors that have the Ability to Preform the Work in the PWS.
Post-Bid
Cincinnati, OH 45220

Reported 02/01/2019 12:00 AM
Project Title

Grease Hoods

Physical Address View project details and contacts
City, State (County) Wright Patterson Air Force Base, OH 445324   (Greene County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Request for Proposals (RFP)
Bids Due View project details and contacts
Estimated Value
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description The cleaning process provided by the contractor shall be in accordance with, but not limited to, the National Fire Protection Association (NFPA) Standard 96 (2011 or most current version). The National Sanitation Foundation Standards and all other local, state, and federal rules and standards shall be used. The contractor shall be certified in the cleaning of grease hood & duct exhaust systems to NFPA 96 Standards. Copies of certifications shall be submitted with their proposals. The systems to be cleaned shall include, but not be limited to, the hoods, back splashguards, ducts, exhaust fan and filter systems from the point of origin to the point of departure at each location. The on/off operation of all equipment (switching devices and all other equipment to be plugged in/out, turned on/off, stopped or started) in or around the area affected by the cleaning process shall follow safety procedures. The UV light system at the Med Center is the only exclusion. The Med Center's facility maintenance division shall schedule UV light maintenance. The contractor shall perform full system cleaning at the Med Center in conjuction with the bi-annual servicing of the UV light system. All equipment moved by the contractor to accommodate the cleaning process shall be placed back in the original location, returned to operational status and remain in operational status until equipment is put back in service by the operators following the contractor cleaning.
Details
Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.
Division 41 - Material Processing and Handling Equipment.
Division 46 - Water and Wastewater Equipment, Oil and Grease Separation and Removal Equipment, Grease Traps.
Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents