Similar Projects
Z--INDE 236306-Replace Chiller Plants/Cooling Towers
Term Contract
Design
$5,000,000 to $10,000,000 est. value
Philadelphia, PA 19106

Replace Chiller Plants/Cooling Towers
Infrastructure
Design
Philadelphia, PA 19106

AHU 1 and AHU 3 Replacement at Central Laboratory
Alteration
Bidding
$3,000,000 to $4,000,000 est. value
Philadelphia, PA 19124

Zinc Orthophospate Storage and Feed System Replacement - HVAC Construction
Alteration
Bidding
$100,000 to $300,000 est. value
Philadelphia, PA 19136

BOILER SERVICE/REPAIR AND WATER TREATMENT
Post-Bid
Philadelphia, PA

Radiator Covers
Post-Bid
$25,000 to $100,000 est. value
Philadelphia, PA

Air Filter
Results
Newtown, PA

High School North Administration HVAC Replacement
Results
Newtown, PA 18940

HVAC and Plumbing
Alteration
Bidding
Philadelphia, PA

Design-Bid-Build (DBB), Building 633 River Water Cooling System, Philadelphia Naval Business Center (PNBC), Philadelphia, PA
Post-Bid
$5,000,000 to $10,000,000 est. value
Philadelphia, PA 19092

Senior Center HVAC
Results
Bensalem, PA 19020

NFPC Inductotherm Coreless Induction Furnace Realignment
Term Contract
Bidding
Philadelphia, PA

Tower Site HVAC Equipment Maintenance
Term Contract
Post-Bid
PA

Bensalem Township Public Works HVAC Replacement
Results
Bensalem, PA 19020

Air Filter
Post-Bid
Newtown, PA 18940

Reported 12/21/2021 12:00 AM
Project Title

Repair OR Replace Ef-18 Exhaust Fan

Physical Address View project details and contacts
City, State (County) Philadelphia, PA 19104 (Bucks, Philadelphia Counties)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Request for Quotations
Bids Due View project details and contacts
Estimated Value
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

The selected vendor/contractor will provide labor, material, and equipment necessary to inspect, diagnose, repair/replace, and verify functionality of the EF-18A Exhaust Fan and related components located on the roof of Building 21. The selected vendor/contractor to provide all equipment, labor, and materials to repair/replace and verify correct functionality of EF-18A exhaust fan and dampers. The exact reason for the fan failure is unknown at this time. Contractor should verify existing conditions with a site visit to determine if the fan should be repaired or replaced. Please submit pricing after site visit. The work may include crane lifts. If the fan can be repaired, the fan will most likely need the following parts replaced: • Upper / Lower Bearings • Drive Shaft • Drive Shaft Sheave • Belts • Drive Motor • Drive Motor Sheave • Verify the dampers on both EF-18 exhaust fans are operating correctly and conduct repairs if necessary.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents