Similar Projects
Solar Power System Design and Installation Master
New Construction, Infrastructure
Bidding

Electrical Switchgear Replacements (STH)
Alteration
Bidding
Minneapolis, MN

Energy Services
Post-Bid
Long Lake, MN

Electrical Maintenance Services
Term Contract
Post-Bid
Minneapolis, Saint Paul, MN

Zachary Lane Elementary School - 2021 LTFM
Renovation
Results
Less than $1,200,000 est. value
Minneapolis, MN 55442

Traffic Control And Bridge Nos. 27409 And 27410
Results
MN

Bde Maka Ska Refectory
New Construction, Infrastructure
Bidding
Minneapolis, MN 55408

Emergency Generator Maintenance and Inspection
Post-Bid
Minneapolis, MN

Traffic Control And Br. No. 9600S/9600N
Results
MN

2022 Lucy Laney Lighting Upgrades
Alteration
Bidding
Minneapolis, MN 55412

Daikin Control Room
Term Contract
Post-Bid
MN 55441

059--Uninterrupted Power Supply (UPS) Service and Maintenance
Results
Minneapolis, MN

Hennepin Avenue Bus Stop Technology
Alteration
Bidding
Minneapolis, MN 55467

Pedestrian Signal Bases
Term Contract
Post-Bid
Minneapolis, MN

Replacement Emergency Generator for Kenny School and Olson School
Results
Minneapolis, MN 55419

Reported 03/03/2022 12:00 AM
Project Title

Traffic Signal Cable

Physical Address View project details and contacts
City, State (County) Minneapolis, MN   (Hennepin County)
Category(s) Heavy and Highway, Single Trades
Sub-Category(s) Electric, Traffic Signalization
Contracting Method Competitive Bids.
Project Status Bidding
Bids Due View project details and contacts
Estimated Value
Plans Available from Municipal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Traffic signal cable shall consist of twelve (12) individually insulated No. 14 AWG class ‘B’ stranded un-coated soft copper conductors. The cable insulation shall be rated at 600 volts at 90° C maximum continuous conductor temperature in wet or dry locations. Conductors shall be insulated with flame-retardant cross-linked polyethylene insulation and be PVC jacketed overall. The cable shall be approved for installation in cable trays in accordance with Article 340 of the National Electric Code and for use in Class 1 remote control and signaling circuits per Article 725-11(b) of the National Electric Code. Cable shall be approved for installation in open air, in ducts or conduits, in tray or trough, and be suitable for direct burial. The cable shall be Draka Cableteq, Okonite, Prysmian, or Rockbestos-Surprenant Type TC Tray Cable meeting the identified standards and requirements.

Details

Division 26 - Electrical.
Division 34 - Transportation, Transportation Signaling and Control Equipment, Roadway Signaling and Control Equipment, Traffic Signals, Traffic Control Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents