Similar Projects
Request for proposals for Installation of Natural Gas Generator(s)
Renovation
Bidding
Hamlin, WV 25523

Request for Proposals for1. Metal Building Expansion; 2. Addition/Installation of Electric to Current Metal Building Structure; 3. Seal and Re-Stripe Current Asphalt Pavement; 4. Remove and Replace Existing Exterior Lighting.
Renovation
Bidding
Hamlin, WV 25523

TASK ORDER: IRS ECC-SCADA - Installation of Meters to Existing Power Distribution Units (PDU)
Post-Bid
$1,000,000 to $3,000,000 est. value
Kearneysville, WV 25430

Routine Electrical Repair Work
Post-Bid
Kearneysville, WV 25430

J--BPA - Electrical Work
Results
Kearneysville, WV 25430

Emergency Generator System Dismantling/Replacement
Results
Triadelphia, WV 26059

DHS/FEMA Region III Hazard Mitigation Project
Bidding
Buckhannon, WV

Replace Interior LED Lighting
Post-Bid
Morgantown, WV

Z--NCTC-Campus Wide Electrical Meter Replacement - West Virginia
Results
$100,000 to $250,000 est. value
Shepherdstown, WV

Purchase and Install Commercial Grade Generators
Bidding
Huntington, WV

Guaranteed Energy Savings Contract
Post-Bid
Shepherdstown, WV

Engineering Substation Transformer
Results
Morgantown, WV 26506

DHS/FEMA Region III Hazard Mitigation Project
Post-Bid
Buckhannon, WV 26201

H--Triennial Electrical Maintenance (VA-19-00031986) Tiered Evaluations: This Procurement Is Set-Aside Based on an Order of Priority as Established in 38 U.S.C 8127
Results
Clarksburg, WV

Emergency Generator Contract
Term Contract
Post-Bid
Charleston, WV

Reported 05/09/2020 12:00 AM
Project Title

Replace Dry-Type Transformer - Wheeling, WV

Physical Address View project details and contacts
City, State (County) Wheeling, WV 26003    (Ohio County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Accepting Letters of Interest
Bids Due View project details and contacts
Estimated Value
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

Contractor shall furnish and install one (1) new 75 kVA dry-type transformer. New transformer shall be 3 Phase, with a primary voltage of 480 and a secondary voltage of 208/102. For transformers rated at 15 kVA or larger, use transformers with a 220 degree C (428 degrees F) insulation system not to exceed an 115 degree C (239 degrees F) rise capable of carrying continuously 115 percent of nameplate kVA without exceeding insulation rating at a maximum ambient temperature of 40 degrees C (104 degrees F).

Details

Division 26 - Electrical, Medium-Voltage Transformers, Dry-Type, Medium-Voltage Transformers.
Division 33 - Utilities, Utility Transformers, Dry-Type Utility Transformers.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents