Similar Projects
Reported | 08/18/2021 12:00 AM |
Project Title | Upgrade Base Cheboygan Camera System |
Physical Address | View project details and contacts |
City, State (County) | Cheboygan, MI (Cheboygan County) |
Category(s) | Single Trades |
Sub-Category(s) | Security/Communications |
Contracting Method | Competitive Bids. |
Project Status | Request for Quotations |
Bids Due | View project details and contacts |
Estimated Value | |
Plans Available from | Federal Agency |
Owner | View project details and contacts |
Architect | View project details and contacts |
Description | This Statement of Work (SOW) defines the requirements for a proposed contractor to develop a proposal and cost estimate to provide and install 2 Honeywell HBW2PER1 IP Performance series cameras and 1 Honeywell HBW2PER2. a. An HBW2PER1 camera is to be installed to replace the camera in photo “C” ( see below). 120volts and a coaxial cable connection reside within the mounting post. These cables pass though in ground junction boxes in pictures “A”, “B”, and “E”. b. An HBW2PER1 camera is to be installed to replace the camera in photo “D” ( see below). 120volts and a coaxial cable connection reside within the mounting post. These cables pass though in ground junction boxes in pictures “A”, “B”, and “E”. c. The HB2PER2 Camera is to be installed on the pillar in photo “F”. d. Approximately thirty feet of rigid thick wall ¾ or 1 inch non-metallic conduit shall be installed from the junction box in photos “E” and “F” to the mounting arm for the camera in paragraph 1.2.c. No more than two feet of liquid tight flexible conduit may be used between the camera mount and the rigid conduit. The camera end of the conduit shall be sealed from the elements. Conduit shall be secured to the brick by two fastener nonmetallic conduit. Conduit shall be buried between 18 and 24 inches deep. Trenches shall be backfilled and disturbed turf repaired. e. 120v shall be wired to the camera in para 1.2.c. using wire of insulation type XHHW or THWN appropriate for a 20A circuit. The power can be sourced from the junction box in Photo “E”. All disturbed wiring connection shall be waterproofed upon reconnection. f. If it is determined that new wire is to be run between the connection boxes shown in the photos. The distances are approximately: 50ft from “A” to “E”, 140ft from “E” to “B” and 100 feet from “B” to the first box inside of a building. g. Signals can be sent via wiring or 5.8Ghz wireless bridge. |
||||
Details |
|
||||
Bidder's List | View project details and contacts | ||||
Prospective Bidders | View project details and contacts | ||||
Project Documents |
Engineered Spec Sheet Architectural Plans Other Documents |