Similar Projects
Cleaning of HVAC System SPRO
Post-Bid
Anadarko, OK 73001

Z1da--635-22-148 Correct Research Ventilation System (Va-21-00026378)
Design
Oklahoma City, OK 73104

Z2da--(Con) 635 - Oklahoma City Vamc Replace Lawton Outpatient Clinic Air Cool Chiller (Va-21-00046407)
Post-Bid
$250,000 to $500,000 est. value
Fort Sill, Oklahoma City, OK 73503

Z2da--(Con) 635 - Oklahoma City Vamc Replace Lawton Outpatient Clinic Air Cool Chiller (Va-21-00046407)
Post-Bid
$250,000 to $500,000 est. value
Fort Sill, Oklahoma City, OK 73503

HVAC Maintenance and Repair Project
Results
$200,000 est. value
Oklahoma City, OK

Guthrie GUES and JR High Gym HVAC Renovation
Post-Bid
Guthrie, OK

HVAC Services
Bidding
Lawton, OK 73501

HVAC Systems Water Treatment Program
Alteration
Bidding
Oklahoma City, OK

J041--Chiller #2, #3, & #4, Repair Oklahoma City VA Health Care System Oklahoma City, OK 73104
Term Contract
Bidding
Oklahoma City, OK 73104

HVAC Replacement at Oklahoma City Housing Authority Annex Building
Alteration
Bidding
Oklahoma City, OK 73117

Reported 05/15/2021 12:00 AM
Project Title

H141--HVAC systems Software Building Main

Physical Address View project details and contacts
City, State (County) Muskogee, OK   (Muskogee County)
Category(s) Single Trades
Sub-Category(s) HVAC
Contracting Method Competitive Bids.
Project Status Request for Quotations
Bids Due View project details and contacts
Estimated Value
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

ENVIRONMENTAL CONTROLS DESCRIPTIONS, SPECIFICATION AND WORK STATEMENT Definition(s): Contracting Officer Representative (COR) A person delegated by the Contracting Officer to act for him/her in furnishing technical guidance and advise or generally supervise the work to be performed under the contract. SEBB I/A Schneider Electric Buildings Business I/A (Invensys) SERVICE A.1. The Contractor shall provide preventive maintenance (PM), training, installation, programming, repair/replacement material and consultation. Contractor shall furnish service specialists trained and factory qualified to diagnose, repair and maintain the SEBB I/A Energy Management and Control System to include ,the Niagara Graphical User Interface, enterprise server, gateway software and/or hardware, UNC s (Universal Network Controllers), Micro Zone II controllers, and the associated input and output transducers and digital or pneumatic control devices. As-built drawings and network drawings are available upon request to contracting officer. A.2. The Contractor shall provide SEBB I/A factory authorized service at the Jack C. Montgomery VA Medical Center, Muskogee, OK to include all labor, travel expenses, tools, test equipment, and other incidentals necessary to maintain or restore the listed equipment to operating specifications according to the manufacturer s recommendations. The Contractor shall show proof of being a factory authorized service provider to warranty and repair SEBB I/A products in Oklahoma. The Contractor Technician shall provide service 4 days each month to evaluate, calibrate, repair, install, or perform other work related to the Energy Management and Control System as directed by the Utility System Supervisor. The workday each month shall be from 8:00 to 4:30 p.m., Monday through Friday, and scheduled in advance with the Utility Systems Supervisor.

Details

Division 23 - Heating, Ventilating, and Air Conditioning (HVAC), Instrumentation and Control for HVAC, HVAC Air Distribution, Central HVAC Equipment.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents