Similar Projects
Electrical Upgrades at Jessup Correctional Complex
Alteration
Bidding
$15,000,000 est. value
Jessup, MD 20794

Communications Facility Maintenance at at Baltimore/Washington International Thurgood Marshall and Martin State Airport
Term Contract
Bidding
Glen Burnie, MD

Energy Efficiency Project-48 Units
Post-Bid
Glen Burnie, MD 21060

On-Call Commercial Electrical Work for State Highway Administration Hanover MD Complex
Post-Bid
Less than $50,000 est. value
Hanover, MD 21076

Low Voltage Electrical Services
Results
Laurel, MD

150 KW Generator
Results
Annapolis, MD 21401

Generator and Associated Items
Alteration
Bidding
Annapolis, MD

On-Call Electrical Services at MDOT SHA Locations in Anne Arundel County
Post-Bid
Less than $50,000 est. value
Annapolis, MD 21401

Design/Build Generator Replacement
Term Contract
Results
Annapolis, MD 21401

Envelope and Switchgear Replacements at Baltimore Harbor Tunnel Vent Buildings
Alteration
Bidding
$50,000,001 to $75,000,000 est. value
Baltimore, MD 21226

Emergency/Standby Generator Maintenance and Repair for Jessup Maintenance Facility
Post-Bid
Less than $50,000 est. value
Jessup, MD 20794

JIS Stand-By Power Generator
Term Contract
Results
Annapolis, MD 21401

On-Call Commercial Electrical Work
Term Contract
Bidding
Less than $50,000 est. value
Hanover, MD 21076

UPS Power Supply Units
Post-Bid
Annapolis, MD 21401

Replacement of Electrical Supply Wiring to Leachate Collection System Intermediate Pump Station at Quarantine Road Sanitary Landfill
Results
Curtis Bay, MD 21226

Reported 11/23/2021 12:00 AM
Project Title

200 kVA UPS System

Physical Address View project details and contacts
City, State (County) Baltimore, MD   (Anne Arundel County)
Category(s) Single Trades
Sub-Category(s) Electric
Contracting Method Competitive Bids.
Project Status Accepting Letters of Interest
Bids Due View project details and contacts
Estimated Value
Plans Available from Federal Agency
Owner View project details and contacts
Architect View project details and contacts
Description

200 kVA UPS System for 3T MRI Scanner: - Compatible with existing Philips 3T Ingenia MRI scanner - 480 volt three-phase delta input power (for compatibility with Hospital power mains) - 480 volt three-phase wye output power (for compatibility with Philips MDU/DACC cabinet) - Minimum 200 kVA capacity (for support of MRI console and KKT cBoxX 100 chiller) - Minimum run time of 60 minutes at 80% load (to maintain operation of magnet cold head refrigeration system) - 300 A maximum input current (for compatibility with existing circuit breaker and wiring) - Dry contacts for general alarm (to connect to Hospital’s JCI building management system) - Remote panel to monitor UPS from MRI control room - Emergency power off (EPO) switch for installation in equipment room - 34" maximum depth for all cabinets (to fit available space in 3T MRI equipment room)\ - 108" maximum total width of UPS cabinet plus battery cabinets (to fit available space) - 80" maximum cabinet height (to fit underneath existing overhead HVAC ducts) - Wall-mounted maintenance bypass switch (to perform service without cutting power to critical loads) - SNMP network interface (needed for monitoring system from outside 3T MRI Facility) - Rigging out and disposal of existing Toshiba G8000 UPS and associated battery cabinets, bypass switch and remote monitoring panel - Rigging in of new UPS and associated battery cabinets, bypass switch and accessories - Startup service included for new UPS.

Details

Division 26 - Electrical, Battery Equipment, Static Uninterruptible Power Supply.

Bidder's List View project details and contacts
Prospective Bidders View project details and contacts
Project Documents
 Engineered Spec Sheet
 Architectural Plans
 Other Documents